Herunterladen Inhalt Inhalt Diese Seite drucken

Start Up; Lp Appliances; Inserting The Waste Hose; Operation - Kärcher IVS 100/75 Originalbetriebsanleitung

Vorschau ausblenden Andere Handbücher für IVS 100/75:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
 Bring the appliance to working position
- secure it, if required, with parking
brakes.
 Insert the suction hose into the suction
hose connection.
 Attach the desired accessoried to the
suction hose.
 Ensure that the vacuum material con-
tainer has been inserted properly.
Warning
The highest allowed net impedance at the
electrical connection point (refer to techni-
cal specifications) is not to be exceeded.
In case of confusion regarding the power
impedance present on your connection,
please contact your utilities provider.

LP appliances

LP appliances are equipped with a waste
hose system.

Inserting the waste hose

 Remove all 4 loops of the waste hose
(length: 22 m).
 Open the intake by a rotation to the left
and pull it out towards the bottom.
 Insert the waste hose as shown in the il-
lustration.
 Insert the intake and lock it by clockwise
rotation.
 Pull down the waste hose 40-50 cm.
 Close the end of the waste hose by
means of a cable tie.
16

Start up

 Insert the appliance plug into the mains
socket.
 Turn the On/Off switch to "1".
IVS 100/55 and IVS 100/75
 Insert the appliance plug into the mains
socket.
 Turn the On/Off switch to "1".
 Press "Switch-on appliance" button.

Suction process

 Perform the suction process.
 If necessary, clean or replace the filter
(described in chapter "Care and mainte-
nance").

Cleaning the filter

There is a manometer on the front side of
the appliance; this indicates the suction un-
der-pressure in the device. If the suction
pressure fall below the value given in the
table below you need to switch off the ma-
chine and clean the filter.
IVS 100/40 16,5 kPa 16,5 kPa 15,5 kPa
IVS 100/55 23,0 kPa 22,0 kPa 15,5 kPa
IVS 100/75 27,0 kPa 25,0 kPa 20,0 kPa

IVS 100/40

 Switch off the appliance using the On/
Off switch.
 Move the filter cleaning lever back and
forth several times, but 5 times at least.
IVS 100/55 und IVS 100/75
 Press the "Switch off appliance" switch.
 Move the filter cleaning lever back and
forth several times, but 5 times at least.
If this cleaning does not bring about any im-
provement, then remove the filter and wash
it or replace it (see chapter "Replacing the
filter").
– 4
EN

Operation

IVS 100/40
NW 42
NW 52
NW 72

Werbung

Inhaltsverzeichnis
loading

Inhaltsverzeichnis