14. Technical Data

Display ..............................................................4000 counts (characters)
Measuring rate ..................................................Approx. 3 measuring operations/second
Measuring method V/AC, A/AC ........................TrueRMS (true root mean square)
Measuring line length .......................................Each approx. 90 cm
Measuring impedance ......................................>10MΩ (V-range)
Current probe opening ......................................max. 30 mm
Measuring jacks distance .................................19 mm
Automatic deactivation .....................................15 minutes, can be deactivated
Voltage supply ..................................................3 micro batteries (1.5 V, AAA or LR03)
Power consumption ..........................................Rated approx. 2 mA,
..........................................................................Max. 45 mA (incl. lighting)
..........................................................................Standby (Automatic deactivation) approx. 20 µA
Working conditions ...........................................0 to 30 °C (rel. hum. <80%)
..........................................................................>30 to 40 °C (rel. hum. <75%)
..........................................................................>40 to 50 °C (rel. hum. <45%)
Operating height ...............................................Max. 2000 m
Storage conditions ............................................-20 °C to +60 °C, max. rel. hum. 80%
Weight ..............................................................Approx. 265 g
Dimensions (L x W x H) ....................................228 x 77 x 41 (mm)
Measuring category ..........................................CAT III 600 V
Degree of contamination ..................................2
Safety according to ...........................................EN61010-1, EN61010-2-032, EN61010-2-033
Measurement tolerances
Statement of accuracy in ± (% of reading + display error in counts (= number of smallest points)). The accuracy is
valid for one year at a temperature of +23 °C (± 5 °C), and at a relative humidity of less than 75%, non-condensing.
Temperature coefficient: +0.1 x (specified accuracy)/1 °C.
The measurement can be impaired when the device is operated within a high-frequency electromagnetic field strength.