Alternating current
Range
4.000A
40.00 A
400.0 A
Frequency range 50 – 60 Hz; Overload protection 600 V, 400 A
Measuring position error: Accuracy deviation at uncentred measuring position: +1%
Guaranteed accuracy: 10 - 100 % of the measurement range
TrueRMS crest factor (CF) for non-sinusoidal signals: max. 3.0
CF >1.4 - 2.0
+ 1%
CF >2.0 - 2.5
+ 2.5%
CF >2.5 - 3.0
+ 4%
Alternating voltage
Range
4.000 V
40.00 V
400.0 V
600 V
Frequency range 40 – 400 Hz; Overload protection 600 V; Impedance: 10 MΩ
Guaranteed accuracy: 10 - 100 % of the measurement range
TrueRMS crest factor (CF) for non-sinusoidal signals: max. 3.0
CF >1.4 - 2.0
+ 1%
CF >2.0 - 2.5
+ 2.5%
CF >2.5 - 3.0
+ 4%
Direct voltage
Range
400.0 mV
4.000 V
40.00 V
400.0 V
600 V
Overload protection 600 V; Impedance: 10 MΩ
50
Resolution
0.001 A
0.01 A
0.1 A
Resolution
0.001 V
0.01 V
0.1 V
1 V
Resolution
0.1 mV
0.001 V
0.01 V
0.1 V
1 V
Accuracy
±(2.5% + 38)
±(2.5% + 7)
±(1.8% + 10)
Accuracy
±(1.5% + 7)
±(1.9% + 7)
Accuracy
±(1.3% + 10)
±(1.0% + 2)
±(1.0% + 4)
±(1.3% + 4)