Item
Description
1
UPS
2
Brackets for tower installation and fixing screws
3
Quick guide
4
Warranty leaflet
5
USB cable
AC power cable - 10 A IEC
6
standard version and BS type for the UK versions of
1 kVA and 1.5 kVA)
AC power cable - 16 A IEC
7
standard version and BS type for the UK versions of
2 kVA/3 kVA)
8
Output cables
Extendable guide kit for rack cabinet mounting,
9
compatible with 1U format device
10
Rack brackets and fixing screws
1 to and 1.5 kVA devices.
(1)
2 to and 3 kVA devices.
(2)
Table 2. List of UPS contents.
5.1.4. Contents of EBM battery module.
Check to make sure the package contains the following elements:
1
3
5
7
Fig. 9. Contents of the battery module packaging (EBM).
USER MANUAL
Quantity
1
2
1
1
1
, (Schuko type in its
(1)
1
, (Schuko type in its
(2)
1
2
1
2 + 8
2
4
6
Item
Description
1
EBM battery module
2
Warranty leaflet
3
Quick guide
4
Battery cable with built-in RJ45
Metal plate for joining several modules and screws
5
for fastening
6
Rack brackets and fixing screws
7
Extendable guide kits for mounting in a rack cabinet
Table 3. List of contents for battery module.
Once the reception is completed, it is advisable to re-pack the
UPS until it is put into service in order to protect it against me-
chanical shock, dust, dirt, etc.
The packaging of the device consists of a wooden pallet, card-
board or wooden box, depending on the item, expanded poly-
styrene corners, polyethylene cover and strapping, all of which
are recyclable materials. When the packaging requires dis-
posal, it must be carried out in accordance with current laws.
We recommend keeping the packaging for at least 1 year.
5.1.5. Storage.
The device should be stored in a dry, ventilated location pro-
tected from rain, dust, water splashes and chemical agents. It
is advisable to keep each device and battery unit in its original
packaging, as it has been specifically designed to ensure max-
imum protection during transportation and storage.
For devices that contain Li-ion batteries, the charging
frequency and charge duration indicated in the table
below (which are based on the device"s storage temperature)
must be observed, otherwise the warranty may be invalidated.
Storage
Charging frequency
temperature
35°C ~ 45°C
Every month
25°C ~ 35°C
Every 1-3 months
-10°C ~ 25°C
Every 3-12 months
Table 4. Frequency and duration of Li-ion battery charging
based on storage temperature.
After this period, connect the device to the mains together with
the battery unit if applicable, start it according to the instruc-
tions described in this manual and charge for 12 hours.
Then shut down the device, disconnect it and store the UPS and
batteries in their original packaging, noting the new date for
recharging the batteries on a document as a record or even on
the packaging itself.
Do not store the devices where the ambient temperature ex-
ceeds 50°C or drops below -15°C, as this may cause degrada-
tion of the electrical characteristics of the batteries.
SLC TWIN RT3 LION UNINTERRUPTIBLE POWER SUPPLIES (UPS)
Quantity
1
1
1
1
1
2 + 8
1
Charge duration
1 h @ 5°C ~ 35°C
1 h @ 5°C ~ 25°C
1 h @ 5°C ~ 25°C
51