Herunterladen Inhalt Inhalt Diese Seite drucken

Supported Hart ® Commands - Endress+Hauser iTEMP TMT 122 Bedienungsanleitung

Vorschau ausblenden Andere Handbücher für iTEMP TMT 122:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

iTEMP® HART® Communication
Endress+Hauser
3.2.6 Supported HART
No.
Description
00
Read unique identifier
01
Read primary variable
02
Read p.v. current and percent of range
03
Read dynamic variables and p.v. current
06
Write polling address
11
Read unique identifier associated with tag
12
Read message
13
Read tag, descriptor, date
14
Read primary variable sensor information
15
Read primary variable output information
16
Read final assembly number
17
Write message
18
Write tag, descriptor, date
19
Write final assembly number
34
Write primary variable damping value
35
Write primary variable range values
38
Reset configuration changed flag
40
Enter/Exit fixed primary varaible current mode
42
Perform master reset
44
Write primary variable units
48
Read additional transmitter status
59
Write number of response preambles
108
Write burst mode command number
109
Burst mode control
144
Read matrix parameter
145
Write matrix parameter
148
Upload
149
Download
®
commands
Universal Commands
Common practice
E+H specific
3 Commissioning
Access
r
r
r
r
w
r
r
r
r
r
r
w
w
w
w
w
w
w
w
w
r
w
w
w
r
w
r
w