Herunterladen Inhalt Inhalt Diese Seite drucken

How To Use The Appliance - Eldom Invest Fv08046Tst Montage-, Betriebs- Und Wartungsanleitung

Indirekt beheizte warmwasserspeicher 80-300
Inhaltsverzeichnis
EN
to the mains shall impede the appliance safety, in which it is prohibited to
use. Such consequences are not within the scope of manufacturer or seller
warranty liabilities and shall be at the expense of the party, which has not
observed the present manual instructions.
Only qualified persons are entitled to connect the water heater to the mains
and to check its functionality.

HOW TO USE THE APPLIANCE

The operation of the heater is controlled by the general management of the
system to provide hot tap water. The water heater can not operate
separately.
The thermometer installed (optional) on the appliance external coating
indicates the process of water heating.
WARNING! Do never switch the appliance if there is a chance that the water
in the water tank is frozen! This shall damage both heater and the tank.
WARNING! Do not switch the system in operation if the water tank is empty
or partially full of contained water.
When using the appliance it is possible to hear some weak noise due to the
water flow through the pipelines and the appliance, as well as to the natural
process of expanding and heating.
CORROSION PROTECTION, PREVENTION,
MAINTENANCE
Enameled water heater tanks. In each water heater with enameled tank is
installed additional corrosion protection. It consists of an anode protector
(anode) of special alloy operating only when the water tank is full. Its
average operation life is at most 3 (say: three) years. After this period, a
manufacturer authorized specialist or dealer service company must check
the conditions of the anode. Where necessary it should be replaced with
new one. Compliance with the inspection deadline and timely replacement
of the anode is important for the effective protection of the tank from
corrosion.
Water tanks of high quality chrome-nickel alloy steel. Corrosion protection
and guaranteed long life are secured by correct choice of steel, adequate
design and engineering construction during tank manufacture process.
SERVICE, PREVENTION, MAINTENANCE
In order to secure reliable operation of the water tank in areas with highly
calcareous water it is recommended to clean the limestone accumulated
within. This operation should take place at least once every two years, while
in areas with higher limestone content even more frequently. The
depositions on the enamel coating should not be removed otherwise than
wiped with dry cotton cloth and without using hard tools. Regular limestone
removal and cleaning is particularly important for appliance reliable
operation. It is recommended that during this maintenance operation you
carry out a review of the enameled tank anode condition. These services are
not subject to warranty coverage and must be performed only by qualified
person.
WARNING! In order to secure water heater safe and trouble-free operation,
the combined valve should be checked regularly for reduced permeability.
This is carried out by lifting the lever and waiting 30 to 60 seconds from the
valve side edge to run thick and plenty water. This operation must be carried
out after connecting the heater to the plumbing and when filling of the tank
with water in the process of using the heater not less than once every two
weeks, as well as eventually after stop and start of water supply. When at full
tank by opening the valve does not leak or water flow is weak, there is a
failure and probably the valve is clogged by impurities in the sewage. Using
water heater with a defective valve is strictly prohibited! Stop immediately
using the device! Stop the coolant flow before it enters the heat exchanger!
Contact the nearest authorized by the manufacturer service company!
Otherwise, it will cause damage to the water tank, and could cause tangible
and intangible damages in the room where the water heater is located.
The water heater outer shell and plastic parts can be cleaned using only a
slightly damp soft cotton cloth and never with invasive and/or abrasive
substances and preparations. Before cleaning the appliance, it MUST be
disconnected from the power supply with the additional disconnection
device or by unplugging the plug on the power cord. IT IS FORBIDDEN to
clean the appliance with steam generator. Particular attention should be
paid to prevent wetting of the appliance light switch on its control panel. The
water heater may be switched on in operation only after complete removal of
moisture.
The rules for checking the anode anti-corrosion protection and anode
replacement (please refer to previous section), as well as removal of the
accumulated limestone, must be strictly observed both during and after the
appliance warranty period.
WARRANTY, WARRANTY PERIOD AND
WARRANTY CONDITIONS
The warranty, warranty conditions, warranty period, warranty validity for
purchased appliance and service related manufacturer or vendor liabilities
during the appliance warranty period are listed in the appliance warranty
form. When buying the appliance the warranty form must be filled and
signed both by seller and buyer. Keep the warranty form in a secure place.
In all instances shall be in force the applicable laws, regulations and other
legislation dealing with the rights and obligations of consumer, seller and
manufacturer, and their relationships related to purchased water heater, its
installation, use, servicing and maintenance.
This appliance warranty shall be in force only is it:
џ Is installed in accordance with the instructions for installation and
usage;
џ Is used only for the purpose it is produced and in accordance with the
instructions for installation and usage;
The warranty shall consist of free of charge repairs of any factory related
defaults that may manifest during the warranty period; The repairs shall be
carried out only by reseller authorized experts and/or technicians.
This unit warranty shall not be valid for any damage caused by:
џ Incorrect transportation;
џ Incorrect storage;
џ Incorrect usage;
џ Used with water characteristics beyond the acceptable values for
drinking water quality and in particular: its composition of chlorides
should be less than 250 mg/l, and the electrical conductivity should be
more than 100 µS/cm with pH within limits of 6,5-9,5 for the water
heaters with enameled water tanks, and less than 200 µS/cm for the
water heaters with chrome-nickel steel water tanks;
џ Power supply with a different tension that the nominal one for the
appliance;
џ Damages due to water freezing;
џ Natural disasters, calamities or other force majeure circumstances;
џ Noncompliance with the instructions for installation and usage;
џ In any cases where repair of any damage is performed by
unauthorized person.
In all mentioned above instances repairs shall be paid.
Warranty shall not apply to normal wear parts and components of the
device, parts that are removed during normal use, lighting and signal lamps
and the like, re-painting color of external surfaces, change of shape, size
and location of parts and components that are exposed to impact and
conditions that are not considered normal use.
Lost profits, tangible and intangible damages caused by temporary inability
to use the device during its prevention and repair shall not by covered by the
warranty.
COMPLIANCE WITH THE REQUIREMENTS OF THIS INSTRUCTION
MANUAL IS A PREREQUISITE FOR SAFE OPERATION OF YOUR
PURCHASED PRODUCT AND IS ONE OF THE WARRANTY TERMS AND
CONDITIONS.
IT IS ABSOLUTELY PROHIBITED TO THE USER OR ANY AUTHORIZED
BY HIM PERSON TO UNDERTAKE ANY CHANGES IN THE PRODUCT
DESIGN AND STRUCTURE. FINDINGS OF SUCH ACTIONS SHALL
AUTOMATICALLY TERMINATE THE MANUFACTURER OR DEALER
WARRANTY LIABILITIES.
IN CASE OF NECESSITY, PLEASE CONTACT THE AUTHORIZED BY
THE MANUFACTURER OR SELLER SERVICE CENTERS.
THE MANUFACTURER PRESERVES HIS RIGHT TO STRUCTURAL
CHANGES WITHOUT NOTICE WHERE SUCH SHALL NOT AFFECT
PRODUCT SAFETY.
9
EN

Quicklinks ausblenden:

Inhaltsverzeichnis
loading

Inhaltsverzeichnis