Herunterladen Inhalt Inhalt Diese Seite drucken

Update, Maintenance And Service Offers - Hamma Misceo 3 Anleitung

Vorschau ausblenden Andere Handbücher für Misceo 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Update-, maintenance and service offers
The Misceo 3 is a robust and low-maintenance product if, for operation and handling,
there are normal orderly and clean conditions. We recommend that you send in your
Misceo 3 every 2 years for a:
Article No.:
2002010
2002011
2002012
To keep up with cooling lubricant changes as well as the legal regulations, the Misceo 3 is constantly being
further developed. The user interface is also being continuously developed, simplified and adapted to the
current requirements and regulations. We therefore recommend that the Misceo 3 be sent in every 2 years for
a technical check, installation of the newest update and for cleaning and calibration of the components to
make sure that your Misceo 3 continues to work as well as it has before.
The services offered include the:
2002010 - Cleaning and calibration
During the cleaning and calibration of your Misceo 3, an extensive function check is carried out. Your Misceo 3
will be disassembled, cleaned, reassembled and calibrated. Individual components and seals will be replaced.
A final check ensures a smooth start. If components should be defective, we will offer these separately.
2002011 - Update to the current software version
The user interface of your Misceo 3 is constantly being further developed, simplified and adapted to the
current requirements and regulations. To keep up with the changes to cooling lubricants as well as legal
regulations, an update to the newest software version is recommended every 2 years. To install the update,
you must send in your Misceo 3.
2002012 - Economy package
The economy package includes both services "2002010 - Cleaning and calibration" and "2002011 - Update to
the current software version" at a lower price.
Annual tasks to be performed by you at your site
At your site, an electrical check should be performed once a year, as for all electrical devices, as well as a
function check and visual inspection.
During the function check, check the function of the Misceo 3. The check is OK if the Misceo 3 mixes the
cooling lubricant to the desired volume at the desired concentration and no moisture emerges from the
Misceo 3.
During the visual inspection, check whether the device, the hoses, the cables and the accessories are in
perfect working condition and correctly connected. If a component should not be in perfect working condition
or incorrectly connected, shut down the Misceo 3 and take the appropriate measures. Take a particularly close
look at the live plug-in power supply. If the housing should not be in perfect condition, replace it.
ENG
22
Designation
Cleaning and calibration
Interval recommendation: Every 2 years
Update to the current software version
Interval recommendation: Every 2 years
Savings package: Cleaning, calibration (art. no.: 2002010)
and update (art. no.: 2002011)
Interval recommendation: Every 2 years