Option - Intelligent pressure control option

Article No.:
Designation
2001150
Intelligent pressure control for Misceo for fixed piping
for using a filling gun, a check valve or drain cock.
It is possible to fill several machines using a closed circular pipeline.
Function: If the pressure in a line drops, the Misceo starts the mixing operation and
fills the machine until the pressure rises again due to the closing of a stop valve,
for example.
With the intelligent pressure control, filling is possible like at any filling station. When one opens the filling
nozzle, the Misceo fills the machine.
When one closes the filling nozzle again, the Misceo stops and the message "Filling level reached" appears
on the display. The Misceo now waits until the filling nozzle is opened again.
The pressure control also allows you to operate a ring line. Here, manual or automatic valves can be used for
filling.
To start up the pressure control, proceed as for the basic device. When selecting the volume, the infinity
function (see "Infinity function") is often practical.
Start the mixing operation after checking the connections and settings.
After starting the mixing operation, the Misceo 3 will fill your container until the set volume is reached or the
mixing outlet is closed.
Once the line is opened again, the Misceo will continue mixing if there should still be mixing volume left. If
the cooling lubricant concentrate runs out during operation, proceed as you would for the standard device
during filling.. On the screen, you will be continuously informed about the current progress.
Attention: When using the intelligent pressure control, piping is mandatory. When the intelligent pressure
control is used with hoses, the hose could burst as a result of pressure surges, and hose aging and other
influences cannot be ruled out. Here, the use of pressure hoses is recommended.
Recommended piping: Input line, water 1/2"
Protect your water inlet and mixture outlet from pressure shocks and pressure peaks. Pressure shocks and
pressure peaks could damage the Misceo 3. Talk to your installer.
Output line, mixture 3/4"