Introduction

As soon as the Misceo 3 is plugged in, an introduction runs on the display and the self-diagnostics routine
runs. Afterwards, the user-friendly menu is displayed. By pressing any key, this can be skipped.

Language setting

To select your language on the Misceo 3, enter your country code in the main menu under "COUNTRY"
(telephone area code) using the plus and minus keys. Your vernacular language will immediately appear.
Main menu
MAIN
MENU
CONTINUE
COUNTRY
+44
VISCOSITY
130V
CALIBRATE
RELIEVE
COUNTER
Viscosity adjustment
The correctly set viscosity of your cooling lubricant is the basis of the precision and function of your Misceo 3.
The viscosity can be adjusted in the main menu via the plus and minus keys. The viscosity of your cooling
lubricant to be set can normally be found in the DIN data sheet of your cooling lubricant under point 9. The
viscosity units required by the Misceo 3 are mm²/s at 20°C in accordance with DIN 51562.
If the viscosity data is not available or should be incorrect or if the mixing result isn't right, continue with the
"Adjust" step.
Main menu
MAIN
MENU
CONTINUE
COUNTRY
+44
VISCOSITY
130V
CALIBRATE
RELIEVE
COUNTER

Adjusting

If the mixing result is not right, this is normally the result of an incorrectly set viscosity.
(Observe refractometer). You can easily correct this deviation in the main menu with the "ADJUST" function.
To adjust the Misceo 3, proceed as follows:
1.) In the main menu, enter the viscosity from the DIN data sheet of your cooling lubricant next to viscosity
(see "Viscosity setting"). If the viscosity of your cooling lubricant is unknown or unavailable, an average
viscosity of 130 mm²/s can be set.
2.) Blend two buckets of cooling lubricant each with 8 l and 5 %.
3.) The first bucket is not measured, but used for precision. Measure the second bucket of cooling lubricant
with your refractometer (observe the refractometer value).
4.) Go to the main menu via the menu item "Main menu".
5.) Select the menu item "Calibrate" in the main menu.
6.) Enter the measured concentration under "Measuring" in the menu "Calibrate" and confirm this in
"Calculate".
7.) The Misceo 3 will then calculate the new viscosity. Accept the calculated viscosity by simply pressing enter
on the menu item "Apply".
8.) To check this, mix another bucket of cooling lubricant and check the mixture concentration. The
concentration should now be correct.
9.) If the measured concentration is not yet satisfactory, please repeat the introduction beginning at step 4.
In the case of substantial deviations, repeated calibrating may be
1 - Main menu
MAIN
MENU
CONTINUE
COUNTRY
+44
VISCOSITY
130V
CALIBRATE
RELIEVE
COUNTER
+49 German
+44 English
+39 Italian
+33 French
+34 Spanish
Viscosity guide value: 130 mm²/s at 20°C
2 - Calibrate
CALIBRATE
VISCOSITY
VISCOSITY
130V
MIXTURE
5,0%
MEASURING
5,2%
CALCULATE
+31 Dutch
+48 Polish
+358 Finnish
+421 Slovakian
+46 Swedish
+386 Slovenian
+420 Czech
+40 Romanian
+36 Hungarian
3 - Calibrate
CALIBRATE
VISCOSITY
RESULT
136V
APPLY
MAIN
MENU
9
ENG