Herunterladen Inhalt Inhalt Diese Seite drucken

Hamma Misceo 3 Anleitung Seite 48

Vorschau ausblenden Andere Handbücher für Misceo 3:
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Option - Automatic mode option - connection diagram
a Connection sockets, Misceo 3
b Connection plugs, Misceo 3
- for overflow monitor / stop, 3-pin
Art. No.: 72001304
- for automatic system, Min., 4-pin
Art. No.: 72001305
- for automatic system, Max., 5-pin
Art. No.: 72001306
c Connection cable, infinite, 2-wire
(per meter)
- Art. No.: 72001311
d Potential-free contact, machine
e Machine
Emergency Stop
2
1
3
View: on solder contacts STOP
3
2
1
4
View: on solder contacts MIN
3
2
4
1
5
View: on solder contacts MAX
ENG
16
a
b
Connection
Connection
socket
plug
Min., Max. &
Connection plug 3-pin
STOP
Contact 1+3
Connection plug 4-pin
MIN
Contact 1+4
Connection plug 5-pin
MAX
Contact 1+3
Plug
connection
connection
For the signals Minimum, Maximum and
Emergency Stop, three potential-free
switches/contacts/outputs are required.
Float, bottom = contact closed
Float, top = contact open
The connection to the Misceo 3 is made with
three connection plugs (3-, 4- and 5-pin). The
connection plugs are included with delivery. To
mix without the automatic system, 3 jumpers
are included in delivery to bypass the
connection sockets.
c
Connection
Potential-
cable
free
contact
N/C contakt
1
2
3
1
2
3
4
1
2
3
4
5
Solder
Variable
d
e
contact
of the
Machine
STOP
EMERGENCY STOP
MIN
MINIMUM
MAX
MAXIMUM
Variable
EMERGENCY STOP
MAXIMUM
MINIMUM
MIKRO
300

Quicklinks ausblenden:

Werbung

Kapitel

Inhaltsverzeichnis
loading

Inhaltsverzeichnis