Option - Automatic mode option

Article No.:
2001130
The automatic system of the Misceo 3 allows you to automatically fill a central system or single machine via
several filling cycles. To fill automatically, connect your Misceo 3 to your machine or central system. To do this,
use the potential-free switch: minimum, maximum and emergency stop. To ensure smooth installation, please
use the connection diagram of the automatic system.
To start up the automatic system, proceed as for the basic device. When selecting the volume, the infinity
function (see "Infinity function") is often practical.
The entered volume should be sufficient for a several filling cycles. Start the mixing operation after checking the
connections and settings. After starting the mixing operation, the Misceo 3 will fill your container automatically.
When the maximum switch is reached, the Misceo 3 shuts down the mixing operation and when the minimum
switch is reached, the Misceo 3 starts the mixing operation back up until the maximum switch is reached again.
The Misceo 3 repeats this operation until the preset volume has been reached. If the cooling lubricant
concentrate runs out during operation, proceed as you would for the standard device during filling.. If the level of
your container should be between minimum and maximum, it is possible to start manually with "Enter". The
Misceo 3 will now mix your cooling lubricant again from the current state up to maximum in the cooling lubricant
container and goes back to the work routine. On the screen, you will be continuously informed about the current
progress. If the maximum switch should be defective, the emergency stop function will provide additional safety.
When the emergency stop switch is actuated, the Misceo 3 deactivates the mixing.
To deactivate automatic filling, stick the jumpers in at Min., Max. and Stopsocket on the Misceo 3. The jumpers
are included in the scope of delivery.
If you did not order an automatic system with your Misceo 3, you can have this retrofit later. To do this, you will
require retrofitting (Art. No.: 2001131) and the automatic system (Art. No.: 2001130). To retrofit, you must send
in your device.
1 - Filling level
FILLING
<<<
ACHTUNG
LEVEL
>>>
ÜBERWACHUNG
REACHED
FÜLLSTAND
|>~~~~~~~~~~~~<|
ERREICHT
|
|
|MIXTURE
[FEHLER
BEHEBEN]
5.0%|
WEITER
|
100/
MIT
1000
[
L|
]
|--------------|
5/
8
2 - Filling level
FILLING
<<<
ACHTUNG
LEVEL
>>>
ÜBERWACHUNG
REACHED
|>~~~~~~~~~~~~<|
FÜLLSTAND
|START
ERREICHT
[
]|
[FEHLER
|MIXTURE
BEHEBEN]
5.0%|
|
WEITER
100/
MIT
1000
[
L|
]
|--------------|
5/
8
Designation
Automatic system for Misceo for automatic filling
The automatic function uses the floating Min, Max and Emergency Stop switches of
your machine to fill this automatically.
Including 3 connection plugs (Min., Max., Emergency Stop),
3 Jumper (Min., Max., Emergency Stop),
without connecting cable (available separately, article no.: 72001311)
The screen indicates that the filling level has reached the maximum switch.
The screen indicates that the filling level has reached the maximum switch, but the
filling level is already back under the maximum switch, but above the minimum
switch. Refilling manually with the "Enter" key is possible on this screen. Hereby,
filling is done again up to the maximum switch.
15