3.
The display (2) now shows how much pressure is
currently in your item.
10.4 Setting the pressure (Fig. 1)
• The unit of the displayed pressure can be selected
using the button (4). The units [bar], [PSI] or [kPa]
can be displayed.
• You can set the pressure with buttons (3) and (5). Up
to max. 8 bar is possible.
• The desired pressure can be reduced using the but-
ton (5).
• The desired pressure can be increased using the
button (3).
• Switch the device on as described in 10.2. The com-
pressor then pumps up to the pressure preset on the
display and then switches off.
10.5 Establishing connections (Fig. 4-7)
m Attention! Switch the device off for this.
10.5.1 Using the adapter set
The adapter set enables the following additional capa-
bilities:
• Pumping up balls with the help of the ball needle (7).
• The tyre valve adapter (9) enables bicycle tyres and
car tyres to be inflated.
• Filling pools, air mattresses, boats or similar swim-
ming accessories is also possible with the help of
the additional conical adapter (8).
Warning! Observe the recommended tyre pressure
specifications from the tyre manufacturer and the
vehicle manufacturer.
Warning! This device is not calibrated! For a cal-
ibrated measurement value, use a suitable meas-
uring device, e.g. at a petrol station, to check the
tyre pressure.
10.5.2 12V socket (Fig. 8)
1.
Press the selector switch (11) to switch between
220-240 V AC and 12V DC.
2.
AC switch up: Device will be supplied with power
via the mains cable.
3.
DC switch down: Device will now be supplied with
DC power via the 12V connection cable.
4.
The compressor can be connected to a 12V socket
in the car. To do so, plug the connector (15) into
your car's socket.
11. Electrical connection
The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions. The custom-
er's mains connection as well as the extension cable
used must also comply with these regulations.
When working with spray attachments and during tem-
porary use outdoors, the device must be connected to
a residual current circuit breaker with a trigger current
of 30 mA or less.
Damaged electrical connection cable.
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Pressure points, where connection cables are
passed through windows or doors,
• Kinks where the connection cable has been improp-
erly fastened or routed,
• Places where the connection cables have been cut
due to being driven over,
• Insulation damage due to being ripped out of the wall
socket,
• Cracks due to the insulation ageing.
Such damaged electrical connection cables must not
be used and are life-threatening due to the insulation
damage.
Check the electrical connection cables for damage regu-
larly. Ensure that the connection cables are disconnected
from electrical power when checking for damage.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the designation H05VV-F.
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 220-240 V~.
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm².
Connection type Y
If the mains connection cable of this device is dam-
aged, it must be replaced by the manufacturer, their
service department or a similarly qualified person to
avoid dangers.
Connections and repair work on the electrical equip-
ment may only be carried out by electricians.