Assembly | Electrical connection | Relief function
5.2

Electrical connection

WARNING
Faulty electrical connections constitute a fatal hazard.
Risk of electric shock.
►Prior to initial commissioning, check the PE wire is cor-
rectly connected.
ATTENTION
Damage to the RolMotion/D+ M-868 due to incorrect
electrical connection.
►Prior to initial commissioning, check the PE wire is
correctly connected.
Ingress of moisture will damage or even destroy the
RolMotion/D+ M-868.
►For devices with protection class IP 44, the custom-
er-side connection of the cable ends or plugs (cable feed-
through) can also be implemented according to protection
class IP 44.
Damage to the blind due to incorrect travel direction.
►The assignment of the UP/DOWN direction of rotation
with an elero radio transmitter must be checked after the
programming process.
Connect only in de-energised state. To do this, switch
the drive cable so it is de-energised.
1 Press locking mechanism on the motor cable plug to-
wards the cable using a suitable screwdriver.
2 Pull out the plug.
3 Insert the motor cable plug until the lock engages.
Removing and inserting the motor cable plug
Delivery
Removing plug
condition
Fig. 4 Removing and inserting the motor cable plug
5.3
Connection example for RolMotion/D+ M-868
230 V/50 Hz
Inserting plug
3
1
2
© elero GmbH
Fig. 5 Connection diagram for RolMotion/D+ M-868
230 V/50 Hz and cable assignment when using
Hirschmann plug connection STAS-3 (with bridge)
5.4

Commissioning

Important
The drive is in commissioning mode when delivered.
►The end positions must be adjusted using the elero
assembly cable (see Fig. 6) or an elero wall or hand-held
transmitter (see Fig. 7).
►The assembly cable may only be connected to commis-
sion the drive and for adjustment operations

5.4.1 Connection for assembly cable

Fig. 6 Connection for assembly cable
►Switch on mains.
►You can now set the end positions with the elero
assembly cable.

5.4.2 Radio connection (transmitter operation)

Fig. 7 Radio connection (transmitter operation)
►Connect cable wires "UP" and "DOWN" together to
phase L (outer conductor).
►Switch on mains. The drive buzzes and travels upwards
and downwards for a short time.
The drive is in radio mode.
Teaching or deleting the transmitter, fixing or deleting the
blind positions: see instructions for the corresponding hand-
held transmitter.

5.4.3 Operation in non-radio mode

Important
If the drive is to be operated in non-radio mode, follow
the instructions for the RolMotion/D+ M (item
no. 138251201).
5.4.4 Automatic configuration of end positions
Important
To use travel profiles, the upper and lower end positions
must first be set.
(3)
(2)
(1)
EN | 5