End position settings
Defining the
Approaching
ventilation
the ventilation
position in the
position
receiver
Requirement:
Prequisite:
Blind is in the lower
Ventilation posi tion is
end position.
defined.
1. Press the [UP ▲]
• Double click on the
button until the venti-
lation gaps open.
2. Then press the
[STOP ■] button.
The blind stops. The
If no ventilation position
position of the ventila-
is defined, the blind
tion is now saved.
moves to the upper
end position.
Approach to the intermediate position and the ventilation posi-
tion takes place in the quiet mode travel profile (see section 7).
7
Travel profiles
The RolMotion/D+ M-868 drive has two travel profiles: stan-
dard mode and quiet mode.
Standard mode
Travels at high speed
except before the end
positions. The roller shutter
slats are lowered slowly.
Activation in down direction
of travel:
• Briefly press the
[DOWN ▼] button: Trav-
el to lower end position.
When placing the blind
slats onto the end
position, the speed is
reduced.
Activation in up direction of
travel:
• Briefly press the [UP ▲]
button: Travel to upper
end position.
Change to the quiet mode
travel profile:
• Press the travel button
for approx. 3 seconds in
the same direction as the
current direction of travel.
Deleting the
ventilation
position
• Simultaneously
press and hold the
[UP ▲]+[STOP ■]
buttons for approx
[UP ▲] button:
3 seconds.
The blind travels
The position of the ven-
upwards to the saved
tilation is now deleted.
position.
Quiet mode
Travel the full path at a
reduced speed
Activation in down direction
of travel:
• Press the [DOWN ▼]
button for about 3 sec-
onds: Travel at reduced
speed to lower end
position.
• Double click the
[DOWN ▼] button: The
blind travels to the saved
intermediate position (if
this is not defined, travel
to the lower end position).
Activation in up direction of
travel:
• Press the [UP ▲] button
for approx. 3 seconds:
Travel at reduced speed
to the upper end position
• Double click the [UP ▲]
button: The blind travels
to the saved ventilation
position (if this is not de-
fined, travel to the upper
end position).
Change to the standard
mode travel profile:
• Press the travel button
briefly in the same
direction as the current
direction of travel.
The drive responds to the
timer functions of pro-
grammed controllers (Tem-
poTel 2, AstroTec, MultiTec
Touch, Centero Home).
The drive responds to com-
mands from programmed
sensors:
• Sun sensor: Travel to
intermediate position or
lower end position.
8

Troubleshooting

Problem / Error
• The drive does
not start up
• Drive runs only
in one direction
• Drive stops
during travel
• Drive stops
during travel
and then goes
in the opposite
direction
• Drive only runs
in standard
mode
Fig. 8 Troubleshooting the RolMotion/D+ M-868
9

Servicing

The RolMotion/D+ M-868 is maintenance-free.
10

Service/manufacturer's address

After installing the drive, the R+S mechatronics technician
(roller shutter and sun protection mechatronics technician)
must note the installed type of drive and the installation
location in the installation and operating instructions.
Drive designation
____________________
____________________
____________________
____________________
____________________
If malfunctions occur despite proper handling or if the unit
has been damaged, contact your contract partner.
© elero GmbH
Possible cause
Remedial
action
• No power
• Check connec-
supply
tion and elec-
trical voltage
• Drive
• Allow drive to
overheated
cool down
• Faulty
• Check
connection
connection
• Error when
• Re-program
programming
the end
the end
positions
positions
• End positions
• Re-program
incorrectly
the end posi-
programmed
tions
• Travel to
intermediate
position
• Blind difficult to
• Check the
move
smooth
running of the
• Obstacle in
blind
drive path
• Re-program
the end
positions
• End positions
• Perform at
are not yet
least two
programmed
complete
movements
in the up and
down direction
without
interruption
Installation location
(e.g. living room window 2)
_________________________
_________________________
_________________________
_________________________
_________________________
EN | 7
Inhaltsverzeichnis
loading

Inhaltsverzeichnis