Assembly: Mechanical fastening
Hazardous possibly by parts that have become live in the
error state.
►Electrical connection is described in the operating and
installation instructions included cable bushing.
CAUTION
Risk of injury due to malfunctions due to improper installa-
tion.
Drive over-winds and possibly destroys parts of application.
►For a safe operation, the end positions must be set /
programmed.
►Training program of the manufacturer for specialists.
Note
Loss of power supply, termination of machine parts and
other malfunctions.
►For safe operation, no false mount must be made and the
end position settings must be carried out during commis-
sioning.
Damage to the RolTop/D+ due to moisture penetration.
►For devices with protection class IP44, the ends of all
cables or connectors must be protected against the
ingress of moisture. This measure must be implemented
immediately after removal of the RolTop/D+ from the
original packaging.
►The drive may only be installed so that it is not irrigated.
Important
In the delivery status (factory setting), the RolTop/D+ in
commissioning mode.
►After successful mounting the drive must be driven alto-
gether 3 times into the upper and 3 times into the lower
end position. The drive must be switched off each time
automatically.
• Programming the end positions is not subject to manda-
tory pattern, i.e. first, the upper end position, and then the
lower end position can be activated, or vice versa. Also
an alternate training of the end positions is possible.
• During the learning phase, the drive moves with reduced
torque in the end positions.
If the entire learning process is complete,
• the drive moves at reduced speed into the end positions
(except RolTop/D+30).
• relieved the drive at the end positions.
The sunblind is adjusted only after a complete and uninter-
rupted access and exit to the blind.
5.1
Mechanical fastening
Important preliminary consideration:
The working space around the built-in drive is usually very
small. Therefore, before the mechanical installation provide
an overview of the implementation of the electrical connec-
tion (see Section 5.2) and take any necessary.
Note
Damage to the electrical wiring by squeezing or tensile
loading.
►Route all electrical cables so that they are not subjected
to crushing or tensile load.
►Note the bending radius of the cables (at least 50 mm).
►Lay the connection cable in a loop downwards to prevent
water running into the drive.
Damage to the drive by the action of impact forces.
►Insert the drive into the shaft, never thrust the drive into
the shaft or smash onto the drive!
►Never allow the drive to fall!
Damage or destruction of the drive by drilling.
►Never drill into the drive!
Important
Attach the RolTop/D+ only at the appropriate fasteners.
Permanently installed control devices shall be clearly dis-
played.
• The curtain must be fastened to the winding shaft.
• The profile tube must have enough distance to the motor
tube.
• Look for an axial clearance (1-2 mm).
Installation in profile tubes
Ⓐ I nsert the drive with a suitable adapt-
er and traction ring into the profile
tube.
Lay the motor cable protected in or-
der to prevent damage by the driven
component.
Ⓑ S ecure the counter bearings against
axial displacement, e.g. screw shaft
spider or rivet.
Secure drive in axial storage!
Ⓒ S ecure hanging on the shaft!
5.2
Electrical connection
Danger to life due to faulty electrical connection.
Electric shock possible.
►Before commissioning check the correct connection of
the PE conductor.
NOTE
Damage to the RolTop/D+ by faulty electrical connection.
►Before commissioning check the correct connection of
the PE conductor.
Damage or destruction of RolTop/D+ by the penetration of
moisture.
►For units with protection class IP 44, the customer con-
nection of the cable ends or connector (cable bushing)
must also be carried out in accordance with protection
class IP 44.
Damage or destruction of RolTop/D+ for variants with
230 V AC 1 due to faulty control.
►Switch with OFF setting (Dead man) for drives must be
installed within sight of the RolTop/D+, but away from any
moving parts and amounting to about 1.5 m.
Important
For electric connection no transmission and retransmission
of the access line or connector is required as a rule.
Depending upon used mounting plate and/or adapter plate
it is necessary in particular with the RolTop/D+ to remove
this screwed plate before a cable exchange.
Connection only in free of tension status, in addition
drive line without tension
1 Using a suitable screwdriver, press out the lock of the
device connector to the line.
© elero GmbH
WARNING
EN | 5