Assembly (Electrical connection) | Commissioning
Damage or destruction of the drive by drilling.
►Never drill into the drive!
Important
Attach the RolTop only at the appropriate fasteners.
Permanently installed control devices shall be clearly dis-
played.
• The curtain must be fastened to the winding shaft.
• The profile tube must have enough distance to the motor
tube.
• Look for an axial clearance (1-2 mm).
Installation in profile tubes
Ⓐ I nsert the drive with a suitable adapt-
er and traction ring into the profile
tube.
Lay the motor cable protected in or-
der to prevent damage by the driven
component.
Ⓑ S ecure the counter bearings against
axial displacement, e.g. screw shaft
spider or rivet.
Secure drive in axial storage!
Ⓒ S ecure hanging on the shaft!
Only operate the drive horizontally, as intended, with the
connection cable loading out from the sinde and out of the
blind winding area.
5.2
Electrical connection
WARNING
Danger to life due to faulty electrical connection.
Electric shock possible.
►Before commissioning check the correct connection of
the PE conductor.
NOTE
Damage to the RolTop by faulty electrical connection.
►Before commissioning check the correct connection of
the PE conductor.
Damage or destruction of RolTop by the penetration of
moisture.
►For units with protection class IP 44, the customer con-
nection of the cable ends or connector (cable bushing)
must also be carried out in accordance with protection
class IP 44.
Damage or destruction of RolTop for variants with 230 V
AC 1 due to faulty control.
►Switch with OFF setting (Dead man) for drives must be
installed within sight of the RolTop, but away from any
moving parts and amounting to about 1.5 m.
Important
For electric connection no transmission and retransmission
of the access line or connector is required as a rule.
Depending upon used mounting plate and/or adapter plate
it is necessary in particular with the RolTop Type S to
remove this screwed plate before a cable exchange.
Connection only in free of tension status, in addition
drive line without tension
1 Using a suitable screwdriver, press out the lock of the
device connector to the line.
2 Disconnect the plug.
3 Insert connector until the latch engages.
4 | EN
M
1~
1 0 2
oder -taster
Netz
230V/50Hz
PE
N
L
M
1~
boiter de
1 0 2
de volet
reseau electrique
230V/50Hz
PE
N
L
© elero GmbH
Removal and insertion of the device plug
Delivery status
Remove plug
Fig. 4 Removal and insertion of the device plug
5.3
Connection example, RolTop 230 V/50 Hz
M
1~
junction box
power grid
230V/50Hz
PE
N
L
Fig. 5 Circuit diagram RolTop 230 V / 50 Hz and
M
wiring when used with Hirschmann plug STAS 3
1~
Important
The motor control must be interlocked in up / down direc-
tion.
A reversing delay of at least 0,5 seconds must be ensured.
5.4
Parallel connection
scatola di
derivatione
Important
You can connect up to 3 parallel RolTop. Note the maximum
switching capacity of switching.
5.5
Commissioning
rete
230V/50Hz
Important
PE
N
L
The drive is in the delivery in commissioning mode.
►You have to set the end positions with the elero assem-
bly cable.
►Connection of the assembly cable is only admissible for
commissioning of the drive and the setting processes.
Fig. 6 Connection for cable assembly
►Switch on mains.
►You can now set the end positions with the elero assem-
bly cable.
Insert plug
3
1
2
1 0 2
(3)
(3)
(2)
(2)
(1)
(1)
1 0 2