Herunterladen Inhalt Inhalt Diese Seite drucken

Cosmo eXcess Montage- Und Bedienungsanleitung Seite 47

Inhaltsverzeichnis
Verfügbare Sprachen

Verfügbare Sprachen

2. INSTALLATION
CONTROLLER WITH POWER UNIT
F 16 A
DeltaTherm
®
Made in Germany
B
F 16 A
NOTE
It must be possible to disconnect the device from the mains at any time.
Î Install the mains plug so that it is accessible at any time.
Î If this is not possible, install a switch that can be accessed.
Power supply of the controller (A)
Conductor
L
Neutral conductor N
Protective earth conductor
Connection of the electric heater (B) (see figure on page 48)
Out 1
Out N
Protective earth conductor ⏚ Protective earth conductor and shield
0-10 V switching input
External power control
Temperature sensors
S1 = temperature store
(above the electric immersion heater)
S2 = temperature sensor 2 (optional)
S3 = temperature sensor 3 (optional)
Digital switching inputs
DIn1
Smart Remote
DIn2
Smart Remote
Digital switching outputs
DO1
inverter
DO2
not assigned
Bus terminals
The controller is equipped with the VBus
carried out at the terminal marked VBus (either polarity). The sensor module is to be connected
to SM (terminals 7 / 8).
SM = sensor module
VBus = e.g. Datalogger
NOTE
For more details about the commissioning procedure see page 55.
IP20
Power Supply
100 – 240
V~
T16 A
50 – 60 Hz
PV
IP20
A
T16 A
Terminals
17 / 19
Terminals
1 / 2
3 / 4
13 / 14
Terminals
9 / 10
11 / 12
Terminals
21 / 22
23 / 24
for data communication. The connection is to be
®
7 / 8
5 / 6
Bus cable to the
DO2
Din2
sensor module
DO1
Din1
NC
SM
10 V IN
10 V REF
VBus
GND
NC
S2
S3
24
12
S1
DO2
23
11
22
10
DO1
21
9
20
8
NC
19
7
10 V IN
18
6
10 V REF
17
5
GND
Power Supply
16
4
NC
100 ... 240
V~
15
3
50-60 Hz
14
2
S3
13
1
47
Din2
Din1
SM
VBus
S2
S1

Kapitel

Inhaltsverzeichnis

Fehlerbehebung

loading

Inhaltsverzeichnis