B. Drying your room
Press MODE button on the control panel or remote control, the LED of dry
indicator lights up. The fan speed is unable to select. User should connect the hose
to the drain outlet at the bottom of the unit.
Note: In this mode, the fan speed switches over to low speed andthe temperature
cannot be selected.
C. Sleep mode
The sleep mode can be activated when in cool mode.
In cool mode :
After 1 hour the preset temperature is increased by 1 ℃, after another hour the
preset temperature will again be increased by 1 ℃.
5.3.3 TIMER SETTING (1hour-24hours) :
The timer has two ways of operation:
To turn off
(When power on)
To turn on
(When power off)
Cancel timer
5.3.4 Automatic Defrost
At low room temperatures, frost may buildup at the evaporator during operation. The
unit will automatically start defrosting and the POWER LED blinking. The defrost
control sequence is as follows:
A. When the unit operates in the cooling operation, drying operation, the ambient
temperature sensor senses the evaporator coil temperature is below -1°C, after
the compressor will stop operating for 10 minutes or the coil temperature up to
7℃, the unit restart to cool operating mode.
B. When the unit operates in the heating operation, drying operation, once the coil
temperature sensor senses the temperature of the evaporator is below 40℃ and
the differential temperature between coil temperature and room temperature is
below 19℃ after the compressor operation for 20minutes, the unit start defrosting
for 5 minutes and the power indicator blinking.
Press Timer key to
turn on the timer
function.
Press Timer key to
turn on the timer
function.
Press Up /Down repeatedly until the LED shows '00'.
Note: when press POWER will also exit the timer setting.
Press Up /Down
repeatedly to set the
delay OFF time.
Press Up /Down
repeatedly to set the
delay ON time.