Continuous drainage
The self-evaporating system uses the collected water to cool the condenser coils for
better efficient performance. It is no need to empty the drainage tank in cooling
operation except in drying operation and high humidity conditions. The condensate
water evaporates at the condenser and evacuated through the exhaust hose.
For continuous operation or unattended operating in drying operation, please
connect the attached drain hose to the unit. Condensate water can be automatically
flow into a bucket or drain by gravity.
Switch off the unit before operating.
Remove the plug of the water outlet opening,
and keep it in safe area.
Securely and properly connect the drain hose
and make sure it is not kinked and clear of
obstruction.
Place the outlet of hose over a drain or bucket
and ensure that water could freely flow out of
the unit.
Do not submerge the end of hose into water;
otherwise it can cause "Air Lock" in the hose.
To avoid water spillage:
As the negative pressure of condensate drain pan is large, tilt the drain hose
downward toward the floor. It is appropriate that the degree of inclination
should exceed 20 degrees.
Straighten the hose to avoid a trap existing in the hose.