Handling and Setting up
(pictures
to
)
Pumps that have reached operating tem-
perature may have a surface temperature
at position (Q) of more than 70°C. WARNING!
Do Not Touch.
The oil filling ports (H
, H
), oil sight glasses (I
1
2
oil drain points (K
, K
) and sealing oil pot (G)
1
2
should all be easily accessible. The cooling air
entry (E) and the cooling air exit (F) must have a
minimum distance of 20 cm from any obstruction.
The discharged cooling air must not be re-circu-
lated.
The VWP pumps can only be operated reliably
if they are installed horizontally.
For installations that are higher than
1000 m above sea level there will be a
loss in capacity. For further advice please con-
tact your supplier.
The Roots pumps should be mounted in a horizon-
tal position. Four holes are provided in the foot for
securing.
For free installation without fixation, we
recommend to ensure stability a base frame with
anti-vibration mounts
(optional extras).
When holding down bolts are tightened care should be taken that no stress is transferred to the pump base. Similarly when
connecting the pipework care should be taken and if necessary pipe bellows should be used.
Installation (pictures
to
For operating and installation follow any relevant national standards that are in operation.
1. High-vacuum connection at (A).
Long and/or small bore pipework should be avoided as this tends to reduce the capacity of the pump.
If the suction pipe is longer than 5 m, then a larger diameter than that of the pump flange should be used.
2. Pre-vacuum connection at (B).
The pre-vacuum connection (B) must not be obstructed or partly obscured.
3. Gauge connection (U) for connecting of measuring installations.
4. The lubricating oil (recommended brands see under servicing) for the toothed wheels and bearings can be put into the booth oil filler ports (H
until the oil level shows at the middle of the oil sight glasses (I
The shaft sealing oil must be filled in the sealing oil pot (G). The oil level must be visible.
5. The electrical data can be found on the data plate (N) or the motor data plate (P). The motors correspond to DIN/VDE 0530 and have IP 54
protection and insulation class B or F. The connection diagram can be found in the terminal box on the motor (unless a special plug connection
is fitted). Check the electrical data of the motor for compatibility with your available supply (voltage, frequency, permissible current etc.).
6. Connect the motor via a motor starter. It is advisable to use thermal overload motor starters to protect the motor and wiring. All cabling used on
starters should be secured with good quality cable clamps.
We recommend that motor starters fitted with a time delayed trip should be used to prevent the unit running beyond the amperage setting. When
the unit is started cold overamperage may occur for a short time.
7. The electrical control should be designed to start the pre-pump before the Roots pump or simultaneously.
The electrical installation may only be made by a qualified electrician under the observance of EN 60204. The main switch must be
planned through the operator.
Initial Operation (pictures
1.
Remove transportion cover of the pre-vacuum and
2. Connect pipe on pre-vacuum
3.
Protect high-vacuum connection
High-vacuum-connection (AT) against in-
advertent touching secures
Attention: Danger through turning rotary
lobes.
4. Initially switch the pump on and off for a few
seconds to check the direction of rotation
against the direction arrow (O).
5. Connect the suction pipe at (A).
Potential risks for operating personnel
Noise Emission: The worst noise levels con-
sidering direction and intensity (sound power),
measured according to DIN 45635 part 3 (as
per 3. GSGV), are shown in the table at the
back. When working permanently in the vicin-
ity of an operating pump we recommend wear-
ing ear protection to avoid any damage to
hearing.
E
, I
),
1
2
If the pumps are installed on a base plate we would recommend fitting anti-vibration mounts.
)
to
)
high-vacuum connection.
connection
(B).
(A) against inadvertent touching.
N
F
F
S
, I
). After filling make sure the oil filler port is closed.
1
2
M
U
X
a
Q
U
I
1
G
Q
A
B
B
H
G
O
6
1
K
1
Q
H
2
S
I
K
2
2
, H
),
1
2
P