DENTSPLY MULTIMAT C Gebrauchsanweisung Seite 38

Keramikofen
Inhaltsverzeichnis

Werbung

Verfügbare Sprachen
  • DE

Verfügbare Sprachen

  • DEUTSCH, seite 1
Fault:
F 08
19.
= Quick cooling is still on.
F 10
10.
= There was a power failure.
F 15
11.
= A vacuum is still present.
F 16
12.
= Thermal element broken.
F 17
13.
= Thermal element poles
reversed.
F 18
14.
= Thermal element short
circuit.
F 19
15.
= Overheated.
F 20
16.
= Program(s) faulty.
Caution !
Secure upper furnace part with transport safety prior to shipping the unit !
38
Cause:
Idle temperature is not reached yet.
Temporary power failure during firing.
Vacuum system is not being ventilated.
Thermal element broken or interruption in
thermal wiring.
Plus and minus poles of thermal element or
thermal wiring were interchanged.
Thermal element or thermal wiring contact
each other.
The actual temperature is 35 °C above the
theoretical value.
Memory error.
Remedy:
Wait until idle temperature is reached or abort manually
with "C".
Not possible. Please check the firing result.
Contact service technician.
Contact service technician.
Contact service technician.
Contact service technician.
Contact service technician.
The control element deletes the faulty program automatically.
The program must be entered again.