10.4 Executing cuts with the transverse cutting
gauge (Fig. D + 18) (optional)
• Set transverse cutting gauge (14) to the desired an-
gle (see 8.10)
• Perform the cut as described under 10.1.
11. Cleaning and maintenance
Warning! Prior to any adjustment, maintenance or ser-
vice work disconnect the mains power plug!
General maintenance measures Wipe chips and dust
off the machine from time to time using a cloth. In order
to extend the service life of the tool, oil the rotary parts
once monthly. Do not oil the motor. When cleaning the
plastic do not use corrosive product.
Cleaning
Keep all safety devices, air vents and the motor housing
free of dirt and dust as far as possible. Wipe the equip-
ment with a clean cloth or blow it with compressed air
at low pressure. We recommend that you clean the de-
vice immediately each time you have finished using it.
Clean the equipment regularly with a moist cloth and
some soft soap. Do not use cleaning agents or sol-
vents; these could attack the plastic parts of the equip-
ment. Ensure that no water can seep into the device.
The ingress of water into an electric tool i creases the
risk of an electric shock.
Maintenance
There are no parts inside the equipment which require
additional maintenance.
Service information
Please note that the following parts of this product are
subject to normal or natural wear and that the following
parts are therefore also required for use as consumables.
Wear parts*: Carbon brushes, saw blade, table inlays;
v-belt
* Not necessarily included in the scope of delivery!
Spare parts and accessories can be obtained from our
service centre. To do this, scan the QR code on the
cover page.
12. Storage
Store the device and its accessories in a dark, dry
and frost-proof place that is inaccessible to children.
36 | GB
The optimum storage temperature is between 5 and 30˚C.
Cover the electrical tool in order to protect it from dust
and moisture.
Store the operating manual with the electrical tool.
13. Electrical Connection
The installed electric motor is connected and is ready to
work. The connection complies with the relevant VDE
and DIN regulations. The customer-side mains supply
and the used extension line must meet these regulations.
Important information
In the event of an overloading the motor will switch it-
self off. After a cool-down period (time varies) the mo-
tor can be switched back on again.
Defective Electric Connection Lines
Often, insulation damages occur on electrical connec-
tion lines.
Causes are:
• Drag marks if connection lines are led through win-
dow or door clearances.
• Kinks due to improper attachment or routing of the
connection line.
• Cuts caused by running over the connection line.
• Insulation damages caused by pulling the connec-
tion line out of the wall socket.
• Fissures caused by the ageing of the insulation.
Such defective electric connection lines must not be
used and are hazardous due to the insulation damages.
Regularly check the electrical connection lines for dam-
ages. Please make sure that the connection lines are
disconnected from the mains supply during the check.
Electrical connection lines must comply with the rele-
vant VDE and DIN regulations. Only use connection
lines labelled with H05VV-F.
The labelling of the connection cable with the type
specification is required.
AC motor
• The mains voltage must be 220 - 240 V~
• Extension cables up to 25 m long must have a
cross-section of 1.5 mm
Connections and repairs of electrical equipment may
only be carried out by an electrician.