SM
1.16. Operating thermostat
The interior temperatures of the cabinets are controlled by thermostats. During the cooling
phase, the thermostat opens the magnetic valve in the coolant line.
NOTE
For cabinets with an integrated machinery unit, the thermostat (see figure
page 3, figures B1-E1) switches on the compressor in the machinery
compartment.
The operating thermostat of the cabinet is set when the cabinet is started up. The setting takes
into account both the temperature required by the products to be displayed and the operating
temperature of the cabinet. Setting the thermostat to a lower temperature may freeze and stop
the evaporator.
The temperature in the cabinet should be checked at regular intervals.
The operating thermostat is set with factory settings. For the operating thermostat instructions,
see the thermostat's own user manual. In case of problems, contact your service company.
1.16.1.
Machine Status menu
1. Press SET quickly to access the Machine Status menu. If alarms are not present, the label
"SEt" appears.
2. Scroll through the other folders in the menu with UP or DOWN.
Folders: Pb1 (probe 1 value folder), Pb2 (probe 2 value folder), SEt (setpoint setting
folder).
Adjusting the temperature
a. Press SET quickly to access the Machine Status menu. The label of the "SEt" folder
appears.
b. Press SET again to display the Setpoint value. The value appears on the display.
c. Change the Setpoint value with UP or DOWN within 15 seconds.
Displaying probes
When the appropriate label appears, press SET to display the probe value associated to it.
c.16.1.
Programming menu
1. Press SET for more than 5 seconds to enter the Programming menu.
2. Scroll through the folders with UP or DOWN.
3. Press SET to enter the desired folder. The label of the first visible parameter appears.
4. Scroll through the other parameters with UP or DOWN.
5. Press SET quickly to select the desired parameter.
6. Set the desired value with UP or DOWN.
7. Press SET to confirm the selection and move to the next parameter.
NOTE
If you do not press any of the keys for 15 seconds or press FNC to exit
the function, the last value on the display is verified and you return to the
previous display.