775
Power stage set pro-
grammed incorrectly
782* - 783*
Error during update
784*
Waiting for memory assign-
ment
789*
CRC setup failed
794*
Memory structure damaged
901
Channel 1 measurement
error
902
Channel 2 measurement
error
903
Channel 3 measurement
error
904
Channel 4 measurement
error
905
Channel 5 measurement
error
990
Difference between yield
and insolation sensor value
is too large
991
Deviation in the insolation
sensor is too large
992
No values are output by the
insolation sensor or val-
ue(s) are not permitted
993
Incorrect energy report
996
No connection to Fronius
Solar.web
997
Deviation between invert-
ers
104
Behaviour
1. Power stage set or filter PC
board not programmed
1. Occurs once
2. Faulty Recerbo
1. Occurs once
2. Faulty Recerbo
1. Corrupt file in memory
2. Faulty Recerbo
1. Corrupt file in memory
2. Faulty Recerbo
Channel 1 current differs from
the others
Channel 2 current differs from
the others
Channel 3 current differs from
the others
Channel 4 current differs from
the others
Channel 5 current differs from
the others
Difference between the output
of the insolation sensor and the
output of the inverter is too
large
Deviation in the insolation sen-
sor is too large
Insolation sensor does not out-
put any values or outputs un-
authorised values
Missing archive values
No connection to Fronius So-
lar.web
Difference in the kWh value for
the inverters (depending on the
settings in Fronius Solar.web)
Remedy
1. See device -> Info menu:
Search for missing version info
and replace the faulty PC
board
1. Automatic correction
2. Replace Recerbo
1. Automatic correction
2. Replace Recerbo
1. Update software
2. Replace Recerbo
1. Update software
2. Replace Recerbo
Check settings, DC fuses and
modules
Check settings, DC fuses and
modules
Check settings, DC fuses and
modules
Check settings, DC fuses and
modules
Check settings, DC fuses and
modules
Check archive values, shad-
ing, string fuse and check for
faulty modules
Check whether the insolation
sensor is dirty, shaded or faulty
Check insolation sensor wiring
Check archive values in Froni-
us Solar.web server or Data-
logger
1. Check LED status on the
Datalogger
2. Restart Datalogger
3. Check internet connection
4. Check whether the customer
has a timer for switching off the
internet connection and check
that the time interval setting is
not too short
Check the system manage-
ment settings in Fronius So-
lar.web (actual Wpeak for each
inverter and threshold value)
and check shading

Quicklinks ausblenden: