Technical Data
Art.no. ROFUSE Turbo S ...................... 1000004403
Mains voltage ........................................ 230 V
Frequency ............................................. 50 Hz; 60 Hz
Power consumption ............................... 1600 VA, 20 % ED
Output current (nominal current) ........... 60 A
Welding voltage ..................................... 8 – 48 V
Ambient temperature ............................. - 20 °C until + 50 °C*
Area of application ROFUSE Turbo S
Protection type ...................................... IP 54
Transmission interface .......................... USB v 2.0
Storage capacity .................................... 2.000 Welding logs
Dimensions (L x W x H) ........................ about 390 x 390 x 140 mm
Weight ................................................... about 10 kg
Contacts ................................................ 4 mm
*Cooling times vary with the ambient temperature. Direct sunlight should be avoided
2.1
Measurement tolerances
Temperature .......................................... ± 5 %
Voltage .................................................. ± 2 %
Current .................................................. ± 2 %
Resistance ............................................. ± 5 %
3
Storage / transport
The device power connecting cable and the welding cable should be protected from sharp edg-
es.
The welding device should not be subjected to strong mechanical loads.
The device should be stored at temperatures ranging from - 30 to + 70°C.
4
Electrical connection
For construction site distribution boards observe the regulations about the FI protective switch
and only operate the welding device over an FI switch (Residual Current Device, RCD).
Ensure that the mains power network or power generator is fused using fuses of a maximum of
20 A (time-lag).
Only appropriately use approved and registered extensions cables with the following conductor
cross-sections.
up to 20 m:
more than 20 m: 2.5 mm² (recommended 4.0 mm²); model H07RN-F
The extension cable may only be used when unrolled completely and stretched to avoid over-
heating.
The required power generator nominal output is dependent on the highest power consumption of
the fittings used. Furthermore, the ambient conditions as well as the performance data of the
power generator itself should be taken into account when constructing the connecting conditions
on-site.
Nominal output power of the generator 1-phase, sinusoidal, 220 V - 240 V, 50/60 Hz:
d 20 - d 160
The power generator must be switched on first before the welding equipment can be attached.
The open circuit voltage should be regulated at about 240 volts.
Note: No other consumer should be driven by the same power generator while welding!
1.5 mm² (recommended 2.5 mm²); model H07RN-F
3,2 kW
Fittings until 160 mm
ENGLISH