Cleaning and Maintenance
Important:
Before any maintenance or cleaning work is carried out, disconnect
the appliance from electricity supply and ensure the appliances is completely cool.
Cleaning the Hob Surface
Clean spillages from the hob surface as soon as possible after use. Always
ensure the surface is cool enough before cleaning.
Use a soft cloth or kitchen paper to clean the surface. If the spillage has dried on
the surface, you may need to use a specialist vitro-ceramic glass cleaner, which
is available for most of supermarkets.
Do not use other abrasive cleaners and/or wire wool ect., as it may scratch the
ceramic glass surface of your hob.
Failure Inspection for induction hob
Problem code and solution
Failure code
Supply voltage is below the
E7
rated voltage
Supply voltage is above the
E8
rated voltage
The surface sensor high
E3
temperature
E6
High temperature of IGBT
The surface sensor
E1
disconnection
The surface sensor short
E2
circuit
Eb
The surface sensor failure
E5
IGBT sensor short circuit
E4
IGBT sensor open circuit
Problem
61
Solution
Please inspect whether power
supply is normal. Power on
after the power supply is
normal.
Wait for the temperature of
ceramic plate return to normal.
Touch "ON/OFF" button to
restart unit.
Wait for the temperature of
ceramic plate return to normal.
Touch "ON/OFF" button to
restart unit.
Check whether the fan runs
smoothly;if not, replace the fan.
Check the connection or
replace the ceramic plate
temperature sensor.
Replacd the drive board.