Troubleshooting, remedy
6.1

Maintenance

To ensure the correct function, safety and service life of the device the following points must be
executed in the maintenance interval.
Used only original spare parts, otherwise the warranty expires.
All operations may only be made in unpressurised, electro less and closed state of the device!

6.1.1 Mechanical

SERVICE INTERVAL

First inspection after
25 operating hours
All 50 operating hours
Minimum 1x per year
(at rough conditions shorten the
interval)

6.1.2 Electrics

Service interval
After 25 operating hours
All 50 operating hours
52400020
Maintenance work
Control and tighten all screws and connections.
(The implementation is only allowed by an expert).
Tighten all screws and connections (take care that the tightening torques
according to the property class of the screws are observed).
Check all existing safety elements (such as linchpins) for perfect function and
replace defective safety elements.
Check all existing joints, bolts, guidance's and gears for correct function, if
necessary, adjust or replace it.
Grease all grease nipples (if available) with a grease gun.
Check of all the suspension parts, bolts and straps. Check for corrosion and
safety by an expert.
Maintenance work
Control all electrical connections and/or retighten (the implementation is
only allowed by an expert)
Check all fuses (if existing)
Check the electric cabling for breaks and abrasion, if necessary, replace it
(only qualified personal)