14.3 Electrical installation
WARNING!
Only a qualified person must do
the electrical installation.
The manufacturer is not responsi-
ble if you do not follow the safety
precautions from the chapter
"Safety Information".
This appliance is supplied with a main
plug and a main cable.
14.4 Cable
Cable types applicable for installation or
replacement: H07 RN-F, H05 RN-F, H05
RRF, H05 VV-F, H05 V2V2-F (T90), H05
BB-F.
15. ENVIRONMENT CONCERNS
Recycle the materials with the symbol
. Put the packaging in applicable
containers to recycle it.
Help protect the environment and human
health and to recycle waste of electrical
For the section of the cable refer to the
total power (on the rating plate) and to the
table:
Section of the ca-
Total power
maximum 1380
3 x 0.75 mm²
W
maximum 2300
3 x 1 mm²
W
maximum 3680
3 x 1.5 mm²
W
The hearth cord (green / yellow cable)
must be 2 cm longer than phase and neu-
tral cables (blue and brown cables).
and electronic appliances. Do not dispose
appliances marked with the symbol
with the household waste. Return the
product to your local recycling facility or
contact your municipal office.
ENGLISH
31
ble