www.electrolux.com
12.1 Building In
80
60
520
600
6
580
min. 560
60
20
min. 550
18
20
min. 560
6
3
70
60 520
min. 550
18
20
60
9
20
12.2 Securing the appliance to
the cabinet
548
21
114
589

12.3 Electrical installation

±1
595
This appliance is supplied only with a
main cable.
12.4 Cable
548
21
Cable types applicable for installation or
replacement:
114
H07 RN-F, H05 RN-F, H05 RRF, H05
589
VV-F, H05 V2V2-F (T90), H05 BB-F
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
±1
595
Total power (W)
maximum 1380
maximum 2300
maximum 3680
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5
A
B