Herunterladen Diese Seite drucken

STIEBEL ELTRON OTE 3 Bedienungsanleitung Seite 37

Vorschau ausblenden Andere Handbücher für OTE 3:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

OPERATION
Messages
6.8 Initial state
Example
f On the start screen, press the selection button.
f Open the menu.
Menu
Heating circuit 1
f Press the selection button.
f Open the menu.
Menu
Initial state
The various data is displayed.
f Return to the start screen by pressing the ESC button a
number of times.
ID
Name
01-020 Heating circuit pump
01-021 Mixer
DHW circuit
01-054 Charging electric auxiliary
heater
01-066 Switchover valve/ charge
pump hot water
Heat pump
01-22
Heat generator pump
01-76
Setpoint rotational speed
compressor
01-77
Heat source pump/fan
01-40
Emergency/auxiliary heater 0...100 %
OTE
Description
0: Heating circuit pump OFF
1: Heating circuit pump ON
Position of mixer:
-100 %: Mixer CLOSE
0 %: Both mixer outputs (15, 16) are
switched off
100 % mixer
0: Electric auxiliary heater DHW OFF
1: Electric auxiliary heater DHW ON
0: DHW heating with heat pump OFF
1: DHW heating with heat pump ON
0...100 %
0...100 %
0...100 %
7.
Messages
WARNING Electrocution
ERROR messages may be remedied only by a body
authorised by us.
f Ensure the heat pump is disconnected from the
power supply before starting work.
f Secure the heat pump against reconnection.
Improper alteration of settings by third parties will
result in the cancellation of all warranties and guar-
antees.
Messages are displayed on the device. Above the ESC button
appears "INFO" and an error message.
Overview of error messages
Mo
04/03/2023
Mo 05.01.2015
INFO
INFO
3
1 Emergency mode (reduced set values) is launched by the
controller whenever a fault occurs.
2 The controller identifies three types of fault
ALARM
ERROR
LOCKOUT
3 When "INFO" is displayed, the controller has generated a
fault message.
7.1
ALARM
The ALARM message appears in the event of a faulty sensor. An
exception to this is a failure in the frost protection sensor. If the
fault message appears for a third time, the heat pump is locked.
The heat pump continues to operate in emergency mode.
Notice
Sensor faults can be remedied only by your qualified
contractor or customer support.
f Call your qualified contractor.
f On the start screen, press the ESC button.
f Press the selection button.
f Set the heat pump to "Emergency mode normal" by turn-
ing the selection button.
f Save the settings by pressing the selection button.
f Return to the start screen by pressing the ESC button.
15:41
Reduced emergency mode
Notbetrieb reduziert
ENTER
ALARM
ALARM
MENU
2
1
| 37

Werbung

loading

Verwandte Produkte für STIEBEL ELTRON OTE 3