OPERATION
Calling up system data
6.4 Heat distribution
HEAT DISTRIBUTION
WAERMEVERTEILER
ESC
ESC
1 System temperature
(TPO - temperature at top of buffer) with buffer cylinder/
water distributor
(TWV - heat pump flow temperature) with no buffer cylin-
der and 1x heating circuit
6.5 Reading off the system temperature
f On the start screen, press the selection button.
f Open the menu.
Menu
Heat distributor
f Press the selection button.
f Open the menu.
Menu
Setpoint and actual values
The various data is displayed.
f Return to the start screen by pressing the ESC button a
number of times.
6.6 Statistics
This menu displays the annual values for the thermal energy
generated for heating operation and DHW heating. The values
are listed separately for the heat pump and an external electric
auxiliary heater.
For the electric auxiliary heater, an efficiency of 100 % is as-
sumed. The electrical energy consumption therefore corre-
sponds 1:1 with the generated heating energy.
The first consumption period starts from the commissioning
date. Each consumption period covers one year and is saved
for 4 years.
Viewing the end date of the current period
You can view when the current statistical period is due to end.
When the period has expired, the recorded values are moved
from the current to the next older period.
f On the start screen, press the selection button.
f Open the menu.
Menu
Service Report  / Settings  / Setpoint and actual values  / End date of
current period
f View the date.
f Return to the start screen by pressing the ESC button a
number of times.
OTE
6.6.1 Heat pump
Values
current
52-000 Elec. energy, cur-
rent period
1
52-010 Htg energy, cur-
rent period
52-020 DHW energy, cur-
rent period
MENUE
MENU
52-030 Defr. energy, cur-
rent period
52-040 Clg energy, current
period
52-050 Seas. perf. factor,
current period (SPF)
1 year ago
52-001 Elec. energy 1
52-011 Htg energy 1
52-021 DHW energy 1
52-031 Defr. energy 1
52-041 Clg energy 1
52-051 Seas.perf. factor
1 (SPF)
2 years ago
52-002 Elec. energy 2
52-012 Htg energy 2
52-022 DHW energy 2
52-032 Defr. energy 2
52-042 Clg energy 2
52-052 Seas.perf. factor
2 (SPF)
3 years ago
52-003 Elec. energy 3
52-013 Htg energy 3
52-023 DHW energy 3
52-033 Defr. energy 3
52-043 Clg energy 3
52-053 Seas.perf. factor
3 (SPF)
4 years ago
52-004 Elec. energy 4
52-014 Htg energy 4
52-024 DHW energy 4
Description
The electrical energy consumption of the heat
pump during the current time period is dis-
played here.
The thermal energy generated by the heat
pump for heating during the current time peri-
od is displayed here.
The thermal energy generated by the heat
pump for DHW heating during the current
time period is displayed here.
The thermal energy generated by the heat
pump for defrosting during the current time
period is displayed here.
The thermal energy generated by the heat
pump for cooling during the current time peri-
od is displayed here.
The seasonal performance factor for the de-
fined time period is displayed here.
The electrical energy consumption of the heat
pump for the previous year is displayed here.
The thermal energy generated by the heat
pump for heating in the previous year is dis-
played here
The thermal energy generated by the heat
pump for DHW heating in the previous year is
displayed here.
The thermal energy generated by the heat
pump for defrosting in the previous year is
displayed here.
The thermal energy generated by the heat
pump for cooling in the previous year is dis-
played here.
The seasonal performance factor for the previ-
ous year is displayed here.
The electrical energy consumption of the heat
pump 2 years ago is displayed here.
The thermal energy generated 2 years ago by
the heat pump for heating is displayed here
The thermal energy generated 2 years ago by
the heat pump for DHW heating is displayed
here.
The thermal energy generated 2 years ago by
the heat pump for defrosting is displayed here.
The thermal energy generated 2 years ago by
the heat pump for cooling is displayed here.
The seasonal performance factor for 2 years
ago is displayed here.
The electrical energy consumption of the heat
pump 3 years ago is displayed here.
The thermal energy generated 3 years ago by
the heat pump for heating is displayed here
The thermal energy generated 3 years ago by
the heat pump for DHW heating is displayed
here.
The thermal energy generated 3 years ago by
the heat pump for defrosting is displayed here.
The thermal energy generated 3 years ago by
the heat pump for cooling is displayed here.
The seasonal performance factor for 3 years
ago is displayed here.
The electrical energy consumption of the heat
pump 4 years ago is displayed here.
The thermal energy generated 4 years ago by
the heat pump for heating is displayed here
The thermal energy generated 4 years ago by
the heat pump for DHW heating is displayed
here.
| 33