FAULT

The appliance has been tested before being
put into service. The information provided be-
low is intended to assist in the identifi cation
and correction of any anomalies and malfunc-
tions which might occur during use.
The user can solve some of these problems
himself, but for others specifi c technical knowl-
edge or skill is required, and so they must only
Fault
The heating elements do
not come on
The appliance does
not heat up to the set
temperature
The control panel does
not come on
Alarm
E00
Safety thermostat failure
Start the cooking well
E01
probe (left well)
Start the cooking well
E.01
probe (left well)
Start the cooking well
E02
probe (right well)
3301300_ut_GB_rev.2
FAULT

TROUBLESHOOTING

Cause
Electrical connection not
made correctly
Safety thermostat tripped
Contactor not receiving elec-
trical power or faulty
Electronic circuit board not
receiving electrical power

TABLE OF ALARM INDICATIONS

Cause
The appliance's functions are disabled so no cooking
cycles can be carried out. Reset the safety thermostat
The appliance's functions are disabled so no cooking
The appliance's functions are disabled so no cooking
be carried out by qualifi ed staff with recog-
nised experience acquired in the specifi c sector
of operation.
NOTE: For all requirements contact
the agents or the headquarters of Angelo Po
which can be found in the contacts section
of the website http://www.angelopo.com.
Carry out the appliance reset (see
Check or replace the contactor
Check or swap the phase wire
(see psgr 21), if the problem persists, call the after-
sales service
The appliance's functions are disabled so no cooking
cycles can be carried out.
NOTE: Contact the after-sales service.
cycles can be carried out.
NOTE: Contact the after-sales service.
cycles can be carried out.
NOTE: Contact the after-sales service.
ENGLISH
Remedy
Check the connection of the
electrical wires
page 21)
Check the condition of the
thermostat and activate any
ignition enabling device
coil
connections
Remedy