Use
3.1
Intended Use
Bewamat A is suitable for partial softening of drin-
king and service water, to protect the water pipes
and the connected fittings, appliances, boilers etc.
from malfunctions and damage caused by lime
incrustation.
The product size must correspond to the expected
conditions of use. Information on this can be found
in DIN 1988-200 and in the technical data in Chapter
12 of these Installation and Operating Instructions.
If the product is intended for commercial use, it
must be checked / approved by a BWT consultant.
Operation of the product with regular functional
checks as well as the execution of the necessary
maintenance measures for the safe operating con-
dition in compliance with the operating conditions
on which the planning and installation are based.
3.2
Foreseeable misuse
Operating the system with parameters other than
those specified in this documentation and in sec-
tion 3.1.
Not adhering to the prescribed maintenance and
service intervals.
Using spare parts and consumables not approved
by BWT.
3.3
Disclaimer
The manufacturer is released from any liability if the
customer intentionally or forcibly removes guards
or safety devices, if the customer wilfully modifies
or circumvents the same, or if the customer does
not follow the instructions in this operating manual
or on the system.
3.4
Other applicable documentation
Observe all documents from suppliers that were
included with delivery. These are considered part
of this documentation and must not be changed
or removed.
4
Function
The unit operates according to the principle of
intelligent regeneration.
Intelligent quantity-dependent regeneration:
When the unit is started, the available supply of
softened water is programmed (depending on the
hardness of the drinking water).
At a user-defined time (e.g. at night), the unit checks
whether the remaining supply of softened water is
sufficient for the following day.
If not, the softening column is regenerated in order
to refill the supply of softened water up to 100%.
In the event of a power failure, the data and the time
are kept (about 1 year).
The unit is equipped with a device that disinfects
the ion exchange resin during the regeneration.
Spring-loaded non-return valves protect all water
connections on the inlet side of the unit.
Automatic activation of regeneration:
If the capacity is not used up within four days, the
electronic system triggers a regeneration.
The system complies with all relevant national and
international standards.
Bewamat 75 A only:
Two capacity levels can be set on the controller,
making the unit suitable for larger applications.
The unit is preset. In case less performance
is necessary, this can be set by after-sales
service.