Indications on the display in normal operation
Go
Electric pump operating
Sb
Electric pump waiting
Utility display items and settings
(keys "MODE" and "SET" 2 seconds )
SP
Setting the set-point pressure ( in bar ). Default: 3 bar
Installer display items and settings
(keys "MODE" and "SET" and "–" 5 seconds )
rC
Setting the rated current of the electric pump ( in A )
rt
Setting the direction of rotation
Setting the rated rotation frequency of the electric pump.
Fn
( in Hz )
od
Setting the operating mode
rP
Setting the pressure drop for restarting ( in bar )
Setting the interconnection address
Ad
(necessary on sets of several electric pumps with exchange)
Eb
Enabling the booster
Technical assistance display items and settings
(keys "MODE" and "SET" and "+" 5 seconds )
tb
Setting the reaction time of the water low block ( in s.)
T1
Running time after low pressure signal
T2
Delay time in event of shutdown conditions
GP
Setting the gain of the PI proportional coefficient
GI
Setting the gain of the PI integral coefficient
Setting the maximum rotation frequency of the electric pump
FS
( in Hz )
Setting the minimum rotation frequency of the electric pump .
FL
( in Hz )
Ft
Setting the low flow rate threshold
CM
Exchange method on sets of 2 electric pumps
AE
Setting the enabling of the anti-block/anti-frost function
i 1
Setting the function of input 1 (float)
i 2
Setting the function of input 2 (set point selection)
i 3
Setting the function of input 3 (enable )
Setting the auxiliary setpoint pressure (in bar)
P1
- depending on input 2 -
o1
Setting the function of output 1 (default value: 2; function: ON alarm )
o2
Setting the function of output 2 (default value: 2; function: ON operating )
Display items of the main values
("MODE"key)
Fr
Display of the current rotation frequency (in Hz)
UP
Pressure display (in bar)
C1
Display of electric pump phase current (in A)
Display of the configuration status of the inverter managed by the control
As
unit
UE
Display of the version of the software with which the appliance is equipped
DISPLAY (keys "SET" and "–" for 2 seconds )
UF
Display of flow
ZF
Display of zero flow
FM
Display of the maximum rotation frequency (in Hz)
tE
Display of the temperature of the power stages (in °C)
bt
Display of the temperature of the electronic board (in °C)
GS
Display of running status
FF
Display of the log of errors and shutdowns
Manual mode (keys "SET" and "+" and "–" 5 seconds )
Setting the test frequency in manual mode (in Hz)
FP
≤ at the set FS value
UP
Pressure display (in bar)
C1
Display of electric pump phase current (in A)
rt
Setting the direction of rotation
UF
Display of flow
ZF
Display of zero flow
System reset ( keys "MODE" and "SET" and "+" and "–" )
General reset ( ZF appears when leaving reset and restarting )
ZF
ENGLISH
Table 8 Menu and Default Values
Menus and Default values
Description
56
Factory parameters
A.D.
A.D.
A.D.
M/T 1.0
M/T 2.2
T/T 3.0
3.0 bar
3.0 bar
3.0 bar
0
0
0
00
00
00
50
50
50
01
01
01
0.5 bar
0.5 bar
0.5 bar
"- -"
"- -"
"- -"
02
02
02
10 s
10 s
10 s
2 s
2 s
2 s
10 s
10 s
10 s
1.0
1.0
0.6
1.0
1.0
1.2
130
130
130
0
0
0
15
15
15
01
01
01
01
01
01
01
01
01
01
01
01
01
01
01
2.5 bar
2.5 bar
2.5 bar
02
02
02
02
02
02
40
40
40
A.D.
T/T 5.5
3.0 bar
0
00
50
01
0.5 bar
"- -"
02
10 s
2 s
10 s
0.6
1.2
130
0
15
01
01
01
01
01
2.5 bar
02
02
40