4 Setup
4.1 Safety Information
WARNING!
Risk of Injury or Damage
This device is recommended to be installed on 
medical bed frames of an appropriate size with bed 
sides or assist rails, to accommodate the device. It is 
preferred that the rails are in the raised position 
whenever the patient is on the bed. Healthcare 
professionals assigned to each case should make the 
final decision whether assist rails are warranted 
after assessing patient risk of entrapment.
Controls on the foot bed end may be obstructed by 
the control unit on a few bed frames. It may be 
necessary to relocate the control unit.
— Before placing the patient on the bed, check that 
connector and power cord are clear of moving 
bed components.
— Operate all motorised bed frame functions 
through their full range of motion to be certain 
that there is no pulling, interference or pinching.
— Take care when positioning connector and cables 
to eliminate the risk of tripping hazards or 
strangulation.
NOTICE!
Inappropriate handling can damage the device.
— It is recommended that two people lift/carry the 
device.        
— Avoid contact with jewellery, nails, abrasive 
surfaces etc.
— Do not drag device.
— Avoid contact with wall, door frames, door 
catches or locks etc.
— Do not transport in roll cages unless completely 
protected from the sharp edges of the cage.
4.2 Installing the System
 1.  Perform one of the following:
 a.  Place the Alternating Pressure Pump on a flat surface 
near the bed.
 b.  Open the hooks B on the back of the Alternating 
Pressure Pump A and install on the outside of the 
bed frame C. 
 2.  Place the mattress overlay on the mattress. The air 
chamber openings should be at the foot end of the bed.
 3.  Slide the two end flaps under the mattress at the head and 
foot end of the bed.
4
 4.  Connect air hoses with fittings F to the air chamber 
openings D on the mattress overlay E. Check that the 
hoses are not kinked or caught under the mattress. 
5 Usage
5.1 Safety Information
WARNING!
Insufficient repositioning of the patient can lead to 
tissue compression and potential injury formation.
To relieve pressure, it is very important for the 
patients to reposition themselves, or to be 
repositioned, on a regular basis.
— Before using the product, always consult a 
qualified healthcare professional for clinical 
judgment.          
— Monitor the patient frequently.
CAUTION!
Risk of damage to the device
If holes are present in the device, there is a risk that 
liquids may ingress and contamination may occur.
— Ensure that the device is not jammed or 
damaged by sharp edges.
— Do not place hypodermic needles, venflons, 
scalpels or other similarly sharp objects on or 
under the device.
— Do not use electrically heated blankets directly 
on or under the device.
— Ensure that all venflons are taped down correctly 
with no sharp edges exposed.
— When using bridging boards or other patient 
transfer aids, check for any sharp edges or burrs 
before use.
— When using the device on a profiling bed ensure 
that the knee break is used before the backrest.
— Attach medical equipment including infusion 
pumps and monitors to appropriate bed 
accessories.
— Avoid cigarette burns and pet claws puncturing 
the device.
5.2 Using the System
 1.  Plug power cord into outlet.
 2.  Turn power switch B to the ON position. The green light 
will be illuminated when the power is on.
 3.  Turn knob A to maximum setting (clockwise). 
 4.  Wait  approx.  15  minutes  for  the  mattress  overlay 
to  inflate. 
Adjusting the Pump
1631420-D