4.3 Installing the roots pump
Required consumable material
● Set of screws for connection flange from the roots pump scope of delivery
● Seal for connection flange from the roots pump scope of delivery
Fig. 5:
1 Crane lug
2 Roots pump connection flange
3 Rotary vane pump intake flange
Installing the roots pump
1. Place the seal in the intake flange of the rotary vane pump.
2. Lift the roots pump according to the transport conditions.
3. Fit the roots pump with the connection flange aligned with the intake flange of the rotary vane
4. Fix the connection flange and the intake flange using the screws.
1
5
Installing the roots pump
pump.
4
Screw (4x DN 63 ISO-F), (8x DN 100 ISO-F)
5
Seal