CONNECTION OF THE CIRCULATION PUMP,
CLIMATE SYSTEM (GP10)
GP10 only required for VVM225.
If the climate system does not already have an external
pump, one can be connected to the accessory card.
Connect the circulation pump (GP10) to AA5-X9:2 (230V),
AA5-X9:1 (N) and X1:3 (PE).
Unit box External
4
3
L
2
N
1
PE
AA5-X9
1
2
3
X1
DIP SWITCH
The DIP switch (S2) on the accessory card (AA5) must
be set as follows.
POOL 310 | GB
GP10
Program settings
Program setting of POOL 310 can be performed via the
start guide or directly in the menu system.
MENU SYSTEM
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
START GUIDE
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
MENU 5.2 - SYSTEM SETTINGS
Activating/deactivating of accessories.
MENU 4.1.1 - POOL
Activating pool heating and setting start and stop tem-
perature.
MENU 5.11.1.2 - HEATING MEDIUM
PUMP/CHARGE PUMP
Setting the heating medium pump's or the charge
pump's speed (depending on model of VVM).
Caution
Also see the Installer Manual for the indoor
module.