Herunterladen Diese Seite drucken

Nibe VVM S325 Installateurhandbuch Seite 19

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

System diagram
NOTE
This is an outline diagram. Actual installations
must be planned according to applicable
standards.
EXPLANATION
CL11
Pool system
AA25
AXC module
BT51
Temperature sensor, pool
EP5
Heat exchanger, pool
GP9
Circulation pump, pool
GP12
Charge pump, pool
HQ4
Particle filter
QN19
Three way valve, pool
EB15
VVM S320/VVM S325
EB101
F2120/F2040/AMS10/HBS05
Designations according to standard IEC 61346-2.
DOCKING TO POOL
Heating of the pool is prioritised according to selected
settings in the indoor module. If the pool sensor (BT51)
is not connected, pool charging is not permitted to start.
OUTLINE DIAGRAM VVM AND POOL 310
-CL11
-CL11-AA25
-CL11-EP5
-CL11-GP12
-CL11-BT51
-CL11-GP9
-CL11-HQ4
-EB101
POOL 310 | GB
-CL11-QN19
-EB15