No.
Type of function / parameter
Calibration of air temperature
A1
A2
A3
Memory function of device status
A4
prior to a power supply failure
A5
Time of screen backlighting
Type of automatic operation
A6
schedule (by weekdays)
Minimum programmed tempera-
A7
Maximum programmed tempera-
A8
A9
Protection against low temperature
Limitation of maximum temperatu-
AA
re of external sensor
Hysteresis of external sensor in N3
AB
Function of detection of an open
AC
window (determination of mini-
Duration of execution of a function
AD
of an open window detection
AE
Resetting to factory settings
ADVANCED SETTINGS B
When the thermoregulator is switched off, press the button
the next parameter press
required values, switch on the thermoregulator.
sensor
Hysteresis
Locking of buttons
ture value
ture value
mode
mum temperature)
. The values are saved automatically. After setting the
Range of parameter
value / function option
–9 °C ÷ 9 °C
0,5–2,5 °C
0: partial locking / 1: full
locking
0: Device restores its state
prior to a power failure
1: Device remains OFF
after power supply returns
2: Device remains ON after
power supply returns
5–30 s
0: 5+2
1: 6+1
2: 7
1–10 °C
20–70 °C
1–10 °C
20–70 °C
1–9 °C
10°C ÷ 20 °C
10–20 min
To enable, press and hold
per 3-5 sec.
Factory value
–1
1 °C
0
0
10
0
5 °C
35 °C
5 °C
28
°C
2 °C
--
10
for 3-5 sec. To go to