TERMOSTAT INSTALLATION, ELECTRIC CONNECTIONS
The TF-WI-FI Mark II is a modern, programmable thermoregulator equipped with
LED control panel intended for controlling electric heating systems. The thermore-
gulator reads the temperature from the built-in sensor and external temperature
sensors, which is included in the kit along with the thermoregulator. Wi-Fi function
and the manufacturer's dedicated TERMOFOL SMART application enable to supervi-
se the heating installation in the mobile manner. Prior to its installation, disassem-
bly, cleaning, inspection or change of the configuration, always disconnect the ther-
moregulator from the power source, e.g., by switching off the power line in the
electric switchboard.
Read the entire contents of this manual before installing the thermoregulator. In the
territory of the Republic of Poland, the electric connections of the thermoregulator
should be made by an electrician holding a valid SEP license for electric installations
up to 1 kV. The electric installation supplying the thermoregulator should meet the
requirements specified in the Regulation of the Minister of Infrastructure and Con-
struction on technical conditions to be met by buildings and their location (Journal
of Laws of 7 June 2019, item 1065) along with the reference standards.
Fig. 2
1. Terminal for connecting the phase wire of the controlled receiver (heating mat, heating foil) supply
2. Terminal for connecting the neutral wire of the controlled receiver (heating mat, heating foil) supply
3. Terminal for connecting the neutral wire of thermoregulator supply
4. Terminal for connecting for phase wire of thermoregulator power supply
5,6. Terminals for connecting the external temperature sensor NTC (polarity is irrelevant)
TERMOFOL TF-WiFi
MARK II
IP20
WiFi
1
2 3
4
5
6