Brief description,
technical data
(for the installer)
The Stiebel Eltron instantaneous water
heater DHF is a hydraulically-controlled
pressure appliance supplying one or several
taps (draw-off points), to heat cold water
to DIN 1988.
The built-in flow volume restrictor
– keeps the flow volume constant in case
of pressure fluctuations in the water
mains and thus the discharge volume.
– limits the flow volume, thus guaranteeing
even in winter a sufficient rise in water
temperature.
The unit can be used in a soft water area
but it is not recommended for use in areas
with hard water (see table 2 for areas of
installation).
A DHB or a DHE should be installed in
hard water areas.
The unit must not be fed by pre-heated
water.
When installing the DHF instan-
taneous heater to replace a DHE
or DHB-S, you must use the "T" piece
which comes with the DHF (Fig. 3
position 3 cold water side). If you do
not, leaks could occur on the DHF.
Special taps
(special instructions for single lever mixers
and thermostatic taps)
– Single lever mixers and thermostat taps
must be suitable for hydraulic
instantaneous hot water heaters
(please observe manufacturers
instructions).
– Low flow rate shower heads should always
be used.
– Flow pressure operating with single lever
mixers should amount to a minimum of
3,5 bar for the DHF 21 (3,0 bar without
flow volume restrictor).
Minimum flow is sufficient when a water
temperature of less than 35 ºC can be
set at position
of the output selector
without any problems.
Technical data
Type
Order-no.
Design
Nominal volume
Nominal overpressure
Weight
Protection class as per VDE
Protection type as per VDE
Approvals
Waterconnection (outside thread)
Electrical connection
Nominal output Step
Step
Flow volume restrictor
Switch on volumes
Partical output
Total output
Switch-on flow pressure (loss of pressure)
with flow volume restrictor
without flow volume restrictor
at flow meter
Application range in water
Total of alkaline earth content
(earlier unit) total hardness
(earlier unit) hardness of area
Tab. 2
DHF 18
DHF 21
07 18 60
07 18 61
l
bar
kg
see the rating label
3/PE ~ 400 V
kW
9
10,5
kW
18
21
l/min
7
8
Color
green
white
l/min
>4,4
>5,2
l/min
>5,5
>6,4
bar
0,90
1,00
bar
0,50
0,60
l/min
5,5
6,4
mol/m
3
ºd
2 (medium hardness)
DHF 24
DHF 27
07 18 62
07 18 63
closed
0,8
10
5
I
IP 25
G 1/2
12
13,5
24
27
9
12
orange
brown
>5,9
>6,7
>7,4
>8,4
1,10
1,40
0,70
0,90
7,4
8,4
≤ 2,5
≤ 14
9