English
Repairs by the user
Malfunction
Heater will not switch on in spite of fully
open water valve.
Repairs by professional
Malfunction
The differential pressure switch does not
switch on the heater in spite of a fully
open hot water valve.
Appliance does not supply hot water in
spite of audible switch-on noise of the
water flow operated power switch.
Servicing
(carried out by a competent person only)
Ensure that the heater is disconnected
from the mains electricity supply before
servicing or repair work is carried out.
Draining / Emptying
The instantaneous water heater must be
drained if there is a danger of frost damage
or if it is not to be used over a longer
period.
The unit is emptied via the cold water pipe
by closing the three-way valve in the
cold water supply (figure 7, position 5) and
loosening the cold water pipes on the
three-way valve.
Descaling / Servicing the flange
The DHF instantaneous heater, due to its
sheathed heating element, is only suitable
for soft water areas (see table 2). Calcifi-
cation/scaling can still occur in soft water
areas. The heating flange can become calci-
fied/covered in limescale. A service flange
is available in order to make this operation
easier.
The order number for the service flange is
detailed in Table 3.
Equipment
Order-no. Service flange
DHF 18
13 93 31
DHF 21
06 94 33
DHF 24
06 94 34
DHF 27
06 94 35
Tab. 3
The service flange is pre-wired and is
supplied with flange gasket, flange screws
and fully detailed instructions.
Cause
The water flow volume required for
switching on is not reached.
– Soiling or calcification of the perlators in
the fixtures or the shower heads.
Cause
The water flow volume required for
switching on is not reached.
– Sieve in container inlet plugged up.
– The safety thermal cut-out switched off
the appliance for safety reasons.
– Heating system defective.
Repair
– Dismantling and decalcification of the
perlators in the taps or the shower
heads.
Repair
– Clean sieve after closing the cold water
supply line (see Fig. 14).
– Remove cause of malfunction. Press
blue button on safety cut-out but do so
only when no pressure is present (i. e.,
with open tap) and with the appliance
disconnected from the electrical mains.
– Replace heating system.