Centrifuge FC5513, FC5513R, FC5513L
1.4.5
Measures for operational safety
• Do not unscrew the two halves of the housing
• Dry off any liquid spills immediately! The instrument is not watertight
• Verify that the equipment's input voltage range and plug type are compatible with the local power supply.
• Only connect the power cord to a properly grounded power receptacle.
• Only use a power cord with a rating that exceeds the specifications on the equipment label.
• Do not position the equipment such that it is difficult to disconnect the power cord from the power receptacle.
• Make sure that the power cord does not pose a potential obstacle or tripping hazard.
• The equipment is for indoor use only. Use the equipment only in dry locations.
• Use only approved accessories.
• Operate the equipment only under ambient conditions specified in these instructions.
• Disconnect the equipment from the power supply when cleaning.
• Do not operate the equipment in hazardous or unstable environments.
• Service should only be performed by authorized personnel.
1.4.6
Danger and precautions
To protect people and environment the following precautions should be observed:
• During centrifugation, the presences of people are prohibited within 30 cm around the centrifuge according
to the regulations of EN 61010-2-020.
• FC5513, FC5513R, FC5513L are not explosion-proof and must therefore not be operated in explosion-
endangered areas or locations. Centrifugation of flammable, explosive, radioactive, or such substances, which
chemically react with high energy, is strictly prohibited. The final decision on the risks associated with the use
of such substances is the responsibility of the user of the centrifuge.
• Never spin toxic or pathogenic material without adequate safety precautions, i.e. centrifugation of buckets /
tubes with missing or defective hermetic sealing is strictly prohibited. The user is obliged to perform appropriate
disinfection procedures in case dangerous substances have contaminated the centrifuge and or its
accessories. When centrifuging infectious substances, always pay attention to the general laboratory
precautions. If necessary, contact your safety officer!
• It is prohibited to run the centrifuge with rotors other than listed for this unit.
• Under no circumstances open the lid of the centrifuge while the rotor is still running or rotating with a speed of
> 2m/s.
1.4.7
Abbreviations used in this manual
Symbol/Abbreviations
RPM
RCF
PCR
PP
PC
accel
decel
prog
Unit
Description
-1
[min
]
revolutions per minute
rpm
[x g]
relative centrifugal force
PCR Polymerase chain reaction
-
Polypropylene
-
Polycarbonate
-
acceleration
-
deceleration
-
program
EN-5