Service and technical support for the installer
For information about specific settings, installation, maintenance and repair work, as an
installer, please contact your local Daikin dealer.

Identification of the product

You will find the unit details on the type plate on the bottom of the unit.
The data plate contains, beside the supplier information and the boiler specification (boiler
type and model name) the following information:
******-yymm******
Product code-Serial No.
YY= year of production, mm = month of production
PIN
Product Identification Number
Data related to Central Heating
Information regarding electrical power supply
Voltage, mains frequency, elmax, IP-class)
PMS
Permissible overpressure in CH circuit in bar
Qn HS
Input related to gross caloric value in kilowatts
Qn Hi
Input related to net caloric value in kilowatts
Pn
Output in kilowatts
BE, DE, FR, IT, PL
Countries of Destination (EN 437)
I2E(s), I2H, IIELL3P,
II2H3P,
Approved unit categories (EN 437)
II2Esi3P
G20-20 mbar
Gas group and gas connection pressure as set at the factory
G25-25 mbar
(EN 437)
B23, .... C93(x)
Approved flue gas category (EN 15502)
Tmax
Max. flow temperature in °C
IPX4D
Electrical protection class
1

SAFETY INSTRUCTIONS

IMPORTANT
This product is intended for domestic use only.
The manufacturer Daikin Europe NV accepts no liability for damage or injury caused by the
failure to (strictly) observe the safety instructions, or negligence during the installation of the
Daikin EHOBG*ABV1 wall-mounted gas boiler and any associated accessories.
This device is not intended for use by people (including children) with reduced physical,
sensory or mental abilities, or lack of experience and knowledge, unless they are given
supervision or instructions on the use of the device by a person who is responsible for their
safety.
The entire installation must meet the applicable local technical and (safety) instructions, for the
gas installation, the electrical installation, smoke extraction installation, drinking water
installation, and central heating installation.
Depending on the year of construction, an Daikin EHOBG*ABV1 may contain a part which
contains ceramic fibres. This can apply to the gasket of the inspection glass and the isolation
package of the front plate. Always use the recommended personal protective
equipment when working with ceramic fibres.