Leak test
5.2
Low-pressure section
WARNING
Risk of fire or explosion hazard
If the leak test is not performed properly on the low-pressure
section, leaks may remain undiscovered.
Only have the gas system checked by an expert.
For experts only
Test conditions:
Maximum test pressure 150 mbar
•
The high-pressure hose and gas cylinder must be connected.
•
Switch o all the gas appliances such as the heating, refrigerator
or gas hob in the recreational vehicle.
Open all quick-acting shut-o valves to the gas appliances and, if
necessary, the gas remote switch.
Disconnect the low-pressure section from the high-pressure
section. To do this, push in the triggering element for the crash
sensor until the yellow reset button jumps out.
Unscrew the screw cap of the test connection.
Connect the regulator test appliance with the test hose to the test
connection.
Check for leaks in accordance with the national regulations
(e.g. 607 in Germany).
Unscrew the regulator test appliance from the test connection.
Screw the screw cap back onto the test connection.
Press the yellow reset button with the T20 Torx pin of the screw
aid in the housing and gently turn in an anti-clockwise direction.