Herunterladen Diese Seite drucken

Truma DuoControl CS Gebrauchsanleitung Seite 50

Vorschau ausblenden Andere Handbücher für DuoControl CS:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Operation
If necessary, press the yellow reset button on the gas pressure
regulator, gently turn in a clockwise direction and hold for 10
seconds.
After any intervention, check the hose connection on the cylinder
valve for leaks (see the "Checking for leaks in the high-pressure
section" chapter).
During a cylinder change, ensure that the high-pressure hoses
from the inlet connection of the gas pressure regulator is always
at a constant gradient to the gas cylinders (Fig. 11).
Fig. 11
After replacing the empty gas cylinder, select it as the new reserve
cylinder. To to this, turn the control knob 180°.
4.3.2
Gas cylinder with clip-on adapter
For handling the clip-on adapter, see the operating instructions for
the clip-on adapter.
Close the valve from the clip-on adapter.
Disconnect the clip-on adapter from the empty gas cylinder.
If a gas filter is present, change the filter pad (see the operating
instructions for the gas filter).
Replace the gas cylinder.
Connect the clip-on adapter to the full gas cylinder.
Open the valve from the clip-on adapter.
If available, press the hose rupture protection on the high-pres-
sure hose.
Set the control knob on the gas pressure regulator to the full gas
50 EN
DuoControl CS
50020-00980 00 08/2022

Werbung

loading