Operation without drip pan
To drill large-format tiles and slabs and on areas which have already been
laid the EFB 152 PX, without drip pan, is placed directly onto the material
to be drilled.
To achieve the appropriate drilling depth, mount the G½"i - G½"a adapter
supplied between working spindle and core bit.
The pump must be placed into a suitable water-filled container (e.g. a
bucket) in order to ensure the necessary supply of water.
We also recommend the use of a water retention ring in combination with a
wet and dry vacuum cleaner (e.g. DSS25A / DSS50A).
Care and Maintenance
Attention!
Before the beginning of maintenance or repair works, you
have to disconnect the plug from the mains.
Repairs may be executed only by appropriately qualified and experienced
personnel.
After every repair the machine has to be inspected by an
electric specialist. Due to its design, the machine needs a minimum of care
and maintenance.
observed:
Always keep the power tool and the ventilation slots clean.
During work, please pay attention that no particles get inside the
machine.
In case of failure, a repair has to be carried out by an authorised
service workshop.
However, the following points always have to be