Tool Protection
Wrong handling can cause damages on the tool and injuries of the user.
Only use accessories recommended by the manufacturer.
By means of a thermal sensor, in case of continuous overload, the motor is
protected against destruction.
automatically and only can be switched on again after a certain cooling
period (about 2 minutes).
depends on the heating of motor winding and ambient temperature.
Only use original accessories made by EIBENSTOCK.
Drill bits with an external thread R ½" can be screwed directly in the work
spindle. Always use drill bits matching the material which has to be drilled
You can treat the machine carefully by using only drill bits that are balanced
and undeformed.
Pay attention that the segments of the tool have enough relief cut toward
the drill bit body.
Drain the drip pan with plug from inside sealed!
The pump is equipped with a filter sponge to protect it
against dirty cooling water.
This should be cleaned regularly.
To clean the pump, take off the push-on grille, remove
the sponge and clean it with clean water.
Press the on/off switch. The cooling period
Drill Bits
In fact, the machine switches off