Fitting the handle
Please fit the handle provided before the machine is started up for the first
time:
Additional handle for hold-down device:
Screw this into the hold-down device and
tighten it with an SW 17 open-ended spanner.
First, check the correspondence between voltage and frequency against
the data mentioned on the identification plate. Voltage differences from
+ 6% to – 10% are allowed.
The EFB 152 PX is made in protection class I.
For protection purposes, the machine can only be run with a GFCI. For this
reason, the EFB 152 PX is standard delivered with an integrated PRCD
protective switch which can be used for a ground socket
Attention!
The PRCD protective switch must not lay down in water.
!
PRCD protective switches must not be used to switch the
tool on and off.
Before starting your work, check the proper function by
pressing the TEST button
Only use 3-wire extension cords with a sufficient cross-section. A cross-
section which is too small might cause a considerable drop in performance
and an overheating of machine and cable.
Water Supply
Electrical Connection
.
The EFB 152 PX has a water circulation by means
of a pump.
Before you start working with the
machine, fill the pan with water until the suction
connection is competely covered. This is the only
way to assure a proper operation.
Only have the machine run with enough water
supply. Dry-drilling could damage the seals
16