Herunterladen Diese Seite drucken

Endress+Hauser promag 30 Ex-Dokumentation Zu Den Betriebsanleitungen Seite 21

Vorschau ausblenden Andere Handbücher für promag 30:

Werbung

Verfügbare Sprachen

Verfügbare Sprachen

Promag 30
Exchange of electronics unit
Warning!
The four positions on the electronics
unit label must match the last four
positions of the order code on the
transmitter nameplate (see Fig. 3),
otherwise the electronics unit may not
be installed. Before reapplying power,
the housing cover must be tightly closed.
Instrument identification
Transmitter Promag 30 (example):
Production location
Instrument group and instru-
ment category according
to Directive 94/9/EC
Labelling of the type of
protection and explosion
group for the Promag 30
measuring system
Sensor Promag F (example):
Production location
Instrument group and instru-
ment category according
to Directive 94/9/EC
Labelling of the type of
protection and explosion
group for the Promag F
Endress+Hauser
These four positions must match the last
four positions of the order code (see Fig. 3)
Module designation
Notified body for Q-Control:
TÜV-Hannover/Sachsen-Anhalt e.V.
CH-4153 Reinach
ENDRESS+HAUSER
PROMAG 30
Order Code:
XXXXXX-XXXXXXXXXXX
XX XXXXXX XX
Ser.No.:
16-62VDC/20-55VAC
50-60Hz
EPD/MSU, ECC, 0.2,B,5P-CAL
I-OUT
II3G
EEx nAC IIC/IIB T4-T5 X
Tamb/Tumg:-20°C...+50°C
i
XA014D/06/../....
Pat. UK EP 618 680
Pat.US 5,479,007
Pat. UK EP 521 169
EP 541 878
Pat.US 4,382,387 4,704,908
Pat.US 5,323,156 5,351,554
Pat. UK 2,084,740
EP 219,725
Notified body for Q-Control:
TÜV-Hannover/Sachsen-Anhalt e.V.
CH-4153 Reinach
ENDRESS+HAUSER
PROMAG F
Order Code:
XXXXXX-XXXXXXXXXXX
XX XXXXXX
Ser.No.:
0.5398/0000/0000
K-factor:
DN25 DIN PN40
Materials:
PTFE 1.4435
Werkstoffe:
130°C
TMmax:
EPD/MSU
II3G EEx nA IIC/IIB T4-T5 X
Tamb./Tumg.: -20...+60°C
i
XA014D/06/../....
Pat.US 5,540,103
Pat.US 4,382,387 4,704,908
Pat.UK 2,084,740 EP 219,725
30XMOD-
B9
1239
129
BC9
Possible contents in the order
code
When exchanging the
electronics unit, these last
four order code positions
0032
must match the four positions
on the electronics unit label
(see Fig. 2)
1999
Year of manufacture
15VA/W
Ambient
temperature range
Corresponding Ex
documentation
0032
1999
Year of manufacture
IP68
Ambient
temperature range
Corresponding Ex
documentation
en
Warning!
Fig. 2
Label on the electronics unit
Fig. 3
Nameplate for the transmitter
Promag 30 Ex version
Fig. 4
Nameplate for the sensor
Promag F Ex version
9

Werbung

loading

Diese Anleitung auch für:

Promag 30f